The Effect of Varying Tension of a Suture Button Construct in Fixation of the Tibiofibular Syndesmosis—Evaluation Using Stress Computed Tomography. Issue 2 (February 2017)
- Record Type:
- Journal Article
- Title:
- The Effect of Varying Tension of a Suture Button Construct in Fixation of the Tibiofibular Syndesmosis—Evaluation Using Stress Computed Tomography. Issue 2 (February 2017)
- Main Title:
- The Effect of Varying Tension of a Suture Button Construct in Fixation of the Tibiofibular Syndesmosis—Evaluation Using Stress Computed Tomography
- Authors:
- Morellato, John
Louati, Hakim
Bodrogi, Andrew
Stewart, Andrew
Papp, Steven
Liew, Allan
Gofton, Wade - Abstract:
- Abstract : Background/Purpose: There have been no studies assessing the optimal biomechanical tension of suture button constructs. The purpose of this study was to assess optimal tensioning of suture button fixation and its ability to maintain reduction under loaded conditions using a stress computed tomography (CT) model. Methods: Ten cadaveric lower limbs disarticulated at the knee were used. The limbs were placed in a modified ankle load frame that allowed for the application of sustained torsional axial or combined torsional/axial loads. The syndesmosis and the deep deltoid ligaments complex were sectioned and the limbs were randomized to receive a suture button construct tightened at 4, 8, or 12 kg. The specimens were loaded under the 3 loading scenarios with CT scans performed after each and at the conclusion of testing. Multiple measurements of translation and rotation were compared with baseline CT scan taken before sectioning. Results: Significant lateral (maximum 5.26 mm) and posterior translation (maximum 6.42 mm) and external rotation (maximum 11.71 degrees) was noted with the 4 kg repair. Significant translation was also seen with both the 8 and the 12 kg repairs; however, the incidence was less than with the 4 kg repair. Significant overcompression (ML = 1.69 mm, B = 2.69 mm) was noted with the 12 kg repair and also with the 8 kg repair (B = 2.01 mm). Conclusion: Suture button constructs must be appropriately tensioned to maintain reduction and re-approximateAbstract : Background/Purpose: There have been no studies assessing the optimal biomechanical tension of suture button constructs. The purpose of this study was to assess optimal tensioning of suture button fixation and its ability to maintain reduction under loaded conditions using a stress computed tomography (CT) model. Methods: Ten cadaveric lower limbs disarticulated at the knee were used. The limbs were placed in a modified ankle load frame that allowed for the application of sustained torsional axial or combined torsional/axial loads. The syndesmosis and the deep deltoid ligaments complex were sectioned and the limbs were randomized to receive a suture button construct tightened at 4, 8, or 12 kg. The specimens were loaded under the 3 loading scenarios with CT scans performed after each and at the conclusion of testing. Multiple measurements of translation and rotation were compared with baseline CT scan taken before sectioning. Results: Significant lateral (maximum 5.26 mm) and posterior translation (maximum 6.42 mm) and external rotation (maximum 11.71 degrees) was noted with the 4 kg repair. Significant translation was also seen with both the 8 and the 12 kg repairs; however, the incidence was less than with the 4 kg repair. Significant overcompression (ML = 1.69 mm, B = 2.69 mm) was noted with the 12 kg repair and also with the 8 kg repair (B = 2.01 mm). Conclusion: Suture button constructs must be appropriately tensioned to maintain reduction and re-approximate the degree of physiological motion at the distal tibiofibular joint. These constructs also demonstrate overcompression of the syndesmosis; however, the clinical effect of this remains to be determined. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 31:Issue 2(2017)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 31:Issue 2(2017)
- Issue Display:
- Volume 31, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 2
- Issue Sort Value:
- 2017-0031-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-02
- Subjects:
- syndesmosis -- suture button fixation -- ankle fracture -- syndesmosis fixation
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000000737 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8304.xml