Sutureless 3F Enable Valve Replacement for Pure Aortic Regurgitation. Issue 11 (4th October 2015)
- Record Type:
- Journal Article
- Title:
- Sutureless 3F Enable Valve Replacement for Pure Aortic Regurgitation. Issue 11 (4th October 2015)
- Main Title:
- Sutureless 3F Enable Valve Replacement for Pure Aortic Regurgitation
- Authors:
- Vola, Marco
Fuzellier, Jean‐François
Anselmi, Amedeo
Campisi, Salvatore
Haber, Benjamain
Isaaz, Karl
Gerbay, Antoine
Ruggieri, Vito Giovanni - Abstract:
- Abstract: Background and Aim: We present our experience in the use of the sutureless valve in patients undergoing aortic valve replacement for pure aortic regurgitation. Methods: Out of 167 patients who underwent sutureless aortic valve implantation with a Medtronic 3f Enable prosthesis in our unit between March 2011 and February 2014, 12 (7.1%) received a sutureless valve for pure aortic regurgitation. Results: Mean age, logistic EuroSCORE, and left ventricular ejection fraction were 72 ± 5 years, 6.3 ± 2.9%, and 52.5 ± 15.3%, respectively. The sutureless valve could be successfully implanted in all cases; nine patients had a full sternotomy (associated coronary artery bypass graft in four cases and associated mitral surgery in five), one patient had a ministernotomy, and two had a thoracoscopic approach. Average cross‐clamping and cardiopulmonary bypass times were 90 ± 30 and 127 ± 51 minutes, respectively. At the outpatient echocardiography, average mean gradient was 10.54 ± 4.99 mmHg and a grade I–II paravalvular leakage (PVL) was detected in the first patient of the cohort (ministernotomy approach). At a mean follow‐up of 11.1 ± 5.5 months, average mean gradient was 9.75 ± 2.87 mmHg, no new PVL was detected, and the known PVL was stable. No pacemaker implantation was required. Conclusions: Implantation of the 3f Enable sutureless valve is technically possible with pure aortic regurgitation in selected patients. Multicenter investigations are necessary to assess theAbstract: Background and Aim: We present our experience in the use of the sutureless valve in patients undergoing aortic valve replacement for pure aortic regurgitation. Methods: Out of 167 patients who underwent sutureless aortic valve implantation with a Medtronic 3f Enable prosthesis in our unit between March 2011 and February 2014, 12 (7.1%) received a sutureless valve for pure aortic regurgitation. Results: Mean age, logistic EuroSCORE, and left ventricular ejection fraction were 72 ± 5 years, 6.3 ± 2.9%, and 52.5 ± 15.3%, respectively. The sutureless valve could be successfully implanted in all cases; nine patients had a full sternotomy (associated coronary artery bypass graft in four cases and associated mitral surgery in five), one patient had a ministernotomy, and two had a thoracoscopic approach. Average cross‐clamping and cardiopulmonary bypass times were 90 ± 30 and 127 ± 51 minutes, respectively. At the outpatient echocardiography, average mean gradient was 10.54 ± 4.99 mmHg and a grade I–II paravalvular leakage (PVL) was detected in the first patient of the cohort (ministernotomy approach). At a mean follow‐up of 11.1 ± 5.5 months, average mean gradient was 9.75 ± 2.87 mmHg, no new PVL was detected, and the known PVL was stable. No pacemaker implantation was required. Conclusions: Implantation of the 3f Enable sutureless valve is technically possible with pure aortic regurgitation in selected patients. Multicenter investigations are necessary to assess the mid‐term benefits of such a device in this subset of patients. … (more)
- Is Part Of:
- Journal of cardiac surgery. Volume 30:Issue 11(2015:Nov.)
- Journal:
- Journal of cardiac surgery
- Issue:
- Volume 30:Issue 11(2015:Nov.)
- Issue Display:
- Volume 30, Issue 11 (2015)
- Year:
- 2015
- Volume:
- 30
- Issue:
- 11
- Issue Sort Value:
- 2015-0030-0011-0000
- Page Start:
- 796
- Page End:
- 800
- Publication Date:
- 2015-10-04
- Subjects:
- Heart -- Surgery -- Periodicals
617.412005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8191 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=jcs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/jocs.12647 ↗
- Languages:
- English
- ISSNs:
- 0886-0440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.863500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8292.xml