Outcomes Associated With Extraction Versus Capping and Abandoning Pacing and Defibrillator Leads. Issue 15 (10th October 2017)
- Record Type:
- Journal Article
- Title:
- Outcomes Associated With Extraction Versus Capping and Abandoning Pacing and Defibrillator Leads. Issue 15 (10th October 2017)
- Main Title:
- Outcomes Associated With Extraction Versus Capping and Abandoning Pacing and Defibrillator Leads
- Authors:
- Pokorney, Sean D.
Mi, Xiaojuan
Lewis, Robert K.
Greiner, Melissa
Epstein, Laurence M.
Carrillo, Roger G.
Zeitler, Emily P.
Al-Khatib, Sana M.
Hegland, Donald D.
Piccini, Jonathan P. - Abstract:
- Abstract : Background: Lead management is an increasingly important aspect of care in patients with cardiac implantable electronic devices; however, relatively little is known about long-term outcomes after capping and abandoning leads. Methods: Using the 5% Medicare sample, we identified patients with de novo cardiac implantable electronic device implantations between January 1, 2000, and December 31, 2013, and with a subsequent lead addition or extraction ≥12 months after the de novo implantation. Patients who underwent extraction for infection were excluded. Using multivariable Cox proportional hazards models, we compared cumulative incidence of all-cause mortality, device-related infection, device revision, and lead extraction at 1 and 5 years for the extraction versus the cap and abandon group. Results: Among 6859 patients, 1113 (16.2%) underwent extraction, whereas 5746 (83.8%) underwent capping and abandonment. Extraction patients tended to be younger (median, 78 versus 79 years; P <0.0001), were less likely to be male (65% versus 68%; P =0.05), and had shorter lead dwell time (median, 3.0 versus 4.0 years; P <0.0001) and fewer comorbidities. Over a median follow-up of 2.4 years (25th, 75th percentiles, 1.0, 4.3 years), the overall 1-year and 5-year cumulative incidence of mortality was 13.5% (95% confidence interval [CI], 12.7–14.4) and 54.3% (95% CI, 52.8–55.8), respectively. Extraction was associated with a lower risk of device infection at 5 years relative toAbstract : Background: Lead management is an increasingly important aspect of care in patients with cardiac implantable electronic devices; however, relatively little is known about long-term outcomes after capping and abandoning leads. Methods: Using the 5% Medicare sample, we identified patients with de novo cardiac implantable electronic device implantations between January 1, 2000, and December 31, 2013, and with a subsequent lead addition or extraction ≥12 months after the de novo implantation. Patients who underwent extraction for infection were excluded. Using multivariable Cox proportional hazards models, we compared cumulative incidence of all-cause mortality, device-related infection, device revision, and lead extraction at 1 and 5 years for the extraction versus the cap and abandon group. Results: Among 6859 patients, 1113 (16.2%) underwent extraction, whereas 5746 (83.8%) underwent capping and abandonment. Extraction patients tended to be younger (median, 78 versus 79 years; P <0.0001), were less likely to be male (65% versus 68%; P =0.05), and had shorter lead dwell time (median, 3.0 versus 4.0 years; P <0.0001) and fewer comorbidities. Over a median follow-up of 2.4 years (25th, 75th percentiles, 1.0, 4.3 years), the overall 1-year and 5-year cumulative incidence of mortality was 13.5% (95% confidence interval [CI], 12.7–14.4) and 54.3% (95% CI, 52.8–55.8), respectively. Extraction was associated with a lower risk of device infection at 5 years relative to capping (adjusted hazard ratio, 0.78; 95% CI, 0.62–0.97; P =0.027). There was no association between extraction and mortality, lead revision, or lead extraction at 5 years. Conclusions: Elective lead extraction for noninfectious indications had similar long-term survival to that for capping and abandoning leads in a Medicare population. However, extraction was associated with lower risk of device infections at 5 years. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 136:Issue 15(2017)
- Journal:
- Circulation
- Issue:
- Volume 136:Issue 15(2017)
- Issue Display:
- Volume 136, Issue 15 (2017)
- Year:
- 2017
- Volume:
- 136
- Issue:
- 15
- Issue Sort Value:
- 2017-0136-0015-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-10-10
- Subjects:
- defibrillators, implantable -- infection -- Medicare -- mortality -- pacemaker, artificial
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.117.027636 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8298.xml