Difference in Diffusion-Weighted Magnetic Resonance Imaging and Diffusion Tensor Imaging Parameters Between Endometrioid Endometrial Adenocarcinoma and Uterine Serous Adenocarcinoma: A Retrospective Study. Issue 8 (October 2017)
- Record Type:
- Journal Article
- Title:
- Difference in Diffusion-Weighted Magnetic Resonance Imaging and Diffusion Tensor Imaging Parameters Between Endometrioid Endometrial Adenocarcinoma and Uterine Serous Adenocarcinoma: A Retrospective Study. Issue 8 (October 2017)
- Main Title:
- Difference in Diffusion-Weighted Magnetic Resonance Imaging and Diffusion Tensor Imaging Parameters Between Endometrioid Endometrial Adenocarcinoma and Uterine Serous Adenocarcinoma
- Authors:
- Tian, Shifeng
Liu, Ailian
Zhu, Wen
Li, Ye
Chen, Lihua
Chen, Anliang
Shen, Jiageng
Song, Qingwei
Wei, Qiang - Abstract:
- Abstract : Objective: This study aimed to elucidate the difference in diffusion-weighted magnetic resonance imaging (DWI) and diffusion tensor imaging (DTI) parameters between endometrioid endometrial adenocarcinoma (EEA) and uterine serous adenocarcinoma (SA). Methods: Data of patients with pathologically confirmed EEA or SA who underwent DWI and DTI scanning between May 2013 and July 2016 were retrospectively analyzed. Apparent diffusion coefficient (ADC) value from DWI and ADC from DTI (ADC T ) map and fractional anisotropy (FA) values from DTI were analyzed and compared statistically. The correlation between ADC and ADC T was analyzed by Pearson correlation analysis. Apparent diffusion coefficient, ADC T, and FA between the 2 groups were compared using independent t test. The effect of ADC, ADC T, and FA in distinguishing EEA and SA was evaluated by receiver operator characteristic curve. Result: Thirty-three patients were enrolled into the study, including 13 cases of SA and 20 cases of EEA. Pearson correlation analysis suggested that the value of ADC was highly related with ADC T in both the SA group ( r = 0.812, P = 0.001) and the EEA group ( r = 0.858, P < 0.001). The value of ADC and ADC T in the SA group was significantly lower than that in the EEA group; FA was significantly higher than that in the EEA group. Receiver operator characteristic curve analysis showed that ADC and ADC T have high sensitivity and specificity; FA has low sensitivity and high specificity.Abstract : Objective: This study aimed to elucidate the difference in diffusion-weighted magnetic resonance imaging (DWI) and diffusion tensor imaging (DTI) parameters between endometrioid endometrial adenocarcinoma (EEA) and uterine serous adenocarcinoma (SA). Methods: Data of patients with pathologically confirmed EEA or SA who underwent DWI and DTI scanning between May 2013 and July 2016 were retrospectively analyzed. Apparent diffusion coefficient (ADC) value from DWI and ADC from DTI (ADC T ) map and fractional anisotropy (FA) values from DTI were analyzed and compared statistically. The correlation between ADC and ADC T was analyzed by Pearson correlation analysis. Apparent diffusion coefficient, ADC T, and FA between the 2 groups were compared using independent t test. The effect of ADC, ADC T, and FA in distinguishing EEA and SA was evaluated by receiver operator characteristic curve. Result: Thirty-three patients were enrolled into the study, including 13 cases of SA and 20 cases of EEA. Pearson correlation analysis suggested that the value of ADC was highly related with ADC T in both the SA group ( r = 0.812, P = 0.001) and the EEA group ( r = 0.858, P < 0.001). The value of ADC and ADC T in the SA group was significantly lower than that in the EEA group; FA was significantly higher than that in the EEA group. Receiver operator characteristic curve analysis showed that ADC and ADC T have high sensitivity and specificity; FA has low sensitivity and high specificity. Conclusions: We suggest that both DWI and DTI could be used in distinguishing EEA from SA. Apparent diffusion coefficient and ADC T possess potential diagnostic value with high sensitivity and specificity. … (more)
- Is Part Of:
- International journal of gynecological cancer. Volume 27:Issue 8(2017)
- Journal:
- International journal of gynecological cancer
- Issue:
- Volume 27:Issue 8(2017)
- Issue Display:
- Volume 27, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 27
- Issue:
- 8
- Issue Sort Value:
- 2017-0027-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-10
- Subjects:
- Apparent diffusion coefficient -- Endometrial cancer -- Fractional anisotropy -- Uterine serous adenocarcinoma
Generative organs, Female -- Cancer -- Periodicals
616.99465 - Journal URLs:
- http://journals.lww.com/ijgc/pages/default.aspx ↗
http://www3.interscience.wiley.com/journal/118544021/toc ↗
https://ijgc.bmj.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IGC.0000000000001054 ↗
- Languages:
- English
- ISSNs:
- 1048-891X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.273500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8298.xml