Effects of pure and hybrid iterative reconstruction algorithms on high-resolution computed tomography in the evaluation of interstitial lung disease. Issue 93 (August 2017)
- Record Type:
- Journal Article
- Title:
- Effects of pure and hybrid iterative reconstruction algorithms on high-resolution computed tomography in the evaluation of interstitial lung disease. Issue 93 (August 2017)
- Main Title:
- Effects of pure and hybrid iterative reconstruction algorithms on high-resolution computed tomography in the evaluation of interstitial lung disease
- Authors:
- Katsura, Masaki
Sato, Jiro
Akahane, Masaaki
Mise, Yoko
Sumida, Kaoru
Abe, Osamu - Abstract:
- Abstract: Objectives: To compare image quality characteristics of high-resolution computed tomography (HRCT) in the evaluation of interstitial lung disease using three different reconstruction methods: model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASIR), and filtered back projection (FBP). Methods: Eighty-nine consecutive patients with interstitial lung disease underwent standard-of-care chest CT with 64-row multi-detector CT. HRCT images were reconstructed in 0.625-mm contiguous axial slices using FBP, ASIR, and MBIR. Two radiologists independently assessed the images in a blinded manner for subjective image noise, streak artifacts, and visualization of normal and pathologic structures. Objective image noise was measured in the lung parenchyma. Spatial resolution was assessed by measuring the modulation transfer function (MTF). Results: MBIR offered significantly lower objective image noise (22.24 ± 4.53, P < 0.01 among all pairs, Student's t -test) compared with ASIR (39.76 ± 7.41) and FBP (51.91 ± 9.71). MTF (spatial resolution) was increased using MBIR compared with ASIR and FBP. MBIR showed improvements in visualization of normal and pathologic structures over ASIR and FBP, while ASIR was rated quite similarly to FBP. MBIR significantly improved subjective image noise (P < 0.01 among all pairs, the sign test), and streak artifacts (P < 0.01 each for MBIR vs. the other 2 image data sets). Conclusion: MBIR providesAbstract: Objectives: To compare image quality characteristics of high-resolution computed tomography (HRCT) in the evaluation of interstitial lung disease using three different reconstruction methods: model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASIR), and filtered back projection (FBP). Methods: Eighty-nine consecutive patients with interstitial lung disease underwent standard-of-care chest CT with 64-row multi-detector CT. HRCT images were reconstructed in 0.625-mm contiguous axial slices using FBP, ASIR, and MBIR. Two radiologists independently assessed the images in a blinded manner for subjective image noise, streak artifacts, and visualization of normal and pathologic structures. Objective image noise was measured in the lung parenchyma. Spatial resolution was assessed by measuring the modulation transfer function (MTF). Results: MBIR offered significantly lower objective image noise (22.24 ± 4.53, P < 0.01 among all pairs, Student's t -test) compared with ASIR (39.76 ± 7.41) and FBP (51.91 ± 9.71). MTF (spatial resolution) was increased using MBIR compared with ASIR and FBP. MBIR showed improvements in visualization of normal and pathologic structures over ASIR and FBP, while ASIR was rated quite similarly to FBP. MBIR significantly improved subjective image noise (P < 0.01 among all pairs, the sign test), and streak artifacts (P < 0.01 each for MBIR vs. the other 2 image data sets). Conclusion: MBIR provides high-quality HRCT images for interstitial lung disease by reducing image noise and streak artifacts and improving spatial resolution compared with ASIR and FBP. … (more)
- Is Part Of:
- European journal of radiology. Issue 93(2017)
- Journal:
- European journal of radiology
- Issue:
- Issue 93(2017)
- Issue Display:
- Volume 93, Issue 93 (2017)
- Year:
- 2017
- Volume:
- 93
- Issue:
- 93
- Issue Sort Value:
- 2017-0093-0093-0000
- Page Start:
- 243
- Page End:
- 251
- Publication Date:
- 2017-08
- Subjects:
- HRCT high-resolution computed tomography -- MBIR model-based iterative reconstruction -- ASIR adaptive statistical iterative reconstruction -- FBP filtered back projection -- MTF modulation transfer function
Iterative reconstruction -- High-resolution computed tomography -- Interstitial lung diseases -- Image noise -- Streak artifact -- Spatial resolution
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2017.06.003 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8280.xml