Patient results and laboratory test accuracy. Issue 1 (4th February 2014)
- Record Type:
- Journal Article
- Title:
- Patient results and laboratory test accuracy. Issue 1 (4th February 2014)
- Main Title:
- Patient results and laboratory test accuracy
- Authors:
- Katayev, Alexander
K. Fleming, James - Abstract:
- Abstract : Purpose: – Traditional quality control materials used for monitoring the clinical laboratory test accuracy might be non-commutable with patient samples and may not detect systematic errors. The aim of this paper is to describe a method to monitor inter-instrument bias using result distributions that are independent of the control's commutability. Design/methodology/approach: – Serum calcium data collected within a laboratory network were assessed. A reference interval was calculated using a computerized, indirect Hoffmann's algorithm using all data across a laboratory network without excluding any results. Results outside the reference interval were considered as the zero-bias distribution. Three allowable bias levels were then calculated to determine the corresponding shift in abnormal results for each bias level in both directions from the zero-bias distribution. The observed result distributions in three laboratories within the network were compared for bias performance after one year of the reference interval study. Findings: – Performance levels for bias were: minimum allowable <1.27 percent; desirable <0.85 percent; and optimal <0.42 percent. Zero bias result distribution above and below the reference interval for calcium was 3.92 percent and 2.53 percent respectively. All three laboratories performed within the desirable allowable bias level. Originality/value: – Bias-monitoring process using patient result distributions allows managers to: assessAbstract : Purpose: – Traditional quality control materials used for monitoring the clinical laboratory test accuracy might be non-commutable with patient samples and may not detect systematic errors. The aim of this paper is to describe a method to monitor inter-instrument bias using result distributions that are independent of the control's commutability. Design/methodology/approach: – Serum calcium data collected within a laboratory network were assessed. A reference interval was calculated using a computerized, indirect Hoffmann's algorithm using all data across a laboratory network without excluding any results. Results outside the reference interval were considered as the zero-bias distribution. Three allowable bias levels were then calculated to determine the corresponding shift in abnormal results for each bias level in both directions from the zero-bias distribution. The observed result distributions in three laboratories within the network were compared for bias performance after one year of the reference interval study. Findings: – Performance levels for bias were: minimum allowable <1.27 percent; desirable <0.85 percent; and optimal <0.42 percent. Zero bias result distribution above and below the reference interval for calcium was 3.92 percent and 2.53 percent respectively. All three laboratories performed within the desirable allowable bias level. Originality/value: – Bias-monitoring process using patient result distributions allows managers to: assess systematic error between laboratory instruments; improve laboratory quality control; and strengthen patient risk management. … (more)
- Is Part Of:
- International journal of health care quality assurance. Volume 27:Issue 1(2014)
- Journal:
- International journal of health care quality assurance
- Issue:
- Volume 27:Issue 1(2014)
- Issue Display:
- Volume 27, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 27
- Issue:
- 1
- Issue Sort Value:
- 2014-0027-0001-0000
- Page Start:
- 65
- Page End:
- 70
- Publication Date:
- 2014-02-04
- Subjects:
- United States of America -- Quality control -- Bias -- Analytical performance -- Laboratory tests -- Reference interval
Medical care -- Quality control -- Periodicals
362.1068 - Journal URLs:
- http://info.emeraldinsight.com/products/journals/journals.htm?id=ijhcqa ↗
http://www.emeraldinsight.com/ ↗ - DOI:
- 10.1108/IJHCQA-09-2012-0092 ↗
- Languages:
- English
- ISSNs:
- 0952-6862
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.275000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8276.xml