Day-and-night glycaemic control with closed-loop insulin delivery versus conventional insulin pump therapy in free-living adults with well controlled type 1 diabetes: an open-label, randomised, crossover study. Issue 4 (April 2017)
- Record Type:
- Journal Article
- Title:
- Day-and-night glycaemic control with closed-loop insulin delivery versus conventional insulin pump therapy in free-living adults with well controlled type 1 diabetes: an open-label, randomised, crossover study. Issue 4 (April 2017)
- Main Title:
- Day-and-night glycaemic control with closed-loop insulin delivery versus conventional insulin pump therapy in free-living adults with well controlled type 1 diabetes: an open-label, randomised, crossover study
- Authors:
- Bally, Lia
Thabit, Hood
Kojzar, Harald
Mader, Julia K
Qerimi-Hyseni, Jehona
Hartnell, Sara
Tauschmann, Martin
Allen, Janet M
Wilinska, Malgorzata E
Pieber, Thomas R
Evans, Mark L
Hovorka, Roman - Abstract:
- Summary: Background: Tight control of blood glucose concentration in people with type 1 diabetes predisposes to hypoglycaemia. We aimed to investigate whether day-and-night hybrid closed-loop insulin delivery can improve glucose control while alleviating the risk of hypoglycaemia in adults with HbA1c below 7·5% (58 mmol/mol). Methods: In this open-label, randomised, crossover study, we recruited adults (aged ≥18 years) with type 1 diabetes and HbA1c below 7·5% from Addenbrooke's Hospital (Cambridge, UK) and Medical University of Graz (Graz, Austria). After a 2–4 week run-in period, participants were randomly assigned (1:1), using web-based randomly permuted blocks of four, to receive insulin via the day-and-night hybrid closed-loop system or usual pump therapy for 4 weeks, followed by a 2–4 week washout period and then the other intervention for 4 weeks. Treatment interventions were unsupervised and done under free-living conditions. During the closed-loop period, a model-predictive control algorithm directed insulin delivery, and prandial insulin delivery was calculated with a standard bolus wizard. The primary outcome was the proportion of time when sensor glucose concentration was in target range (3·9–10·0 mmol/L) over the 4 week study period. Analyses were by intention to treat. This study is registered withClinicalTrials.gov, numberNCT02727231, and is completed. Findings: Between March 21 and June 24, 2016, we recruited 31 participants, of whom 29 were randomised. OneSummary: Background: Tight control of blood glucose concentration in people with type 1 diabetes predisposes to hypoglycaemia. We aimed to investigate whether day-and-night hybrid closed-loop insulin delivery can improve glucose control while alleviating the risk of hypoglycaemia in adults with HbA1c below 7·5% (58 mmol/mol). Methods: In this open-label, randomised, crossover study, we recruited adults (aged ≥18 years) with type 1 diabetes and HbA1c below 7·5% from Addenbrooke's Hospital (Cambridge, UK) and Medical University of Graz (Graz, Austria). After a 2–4 week run-in period, participants were randomly assigned (1:1), using web-based randomly permuted blocks of four, to receive insulin via the day-and-night hybrid closed-loop system or usual pump therapy for 4 weeks, followed by a 2–4 week washout period and then the other intervention for 4 weeks. Treatment interventions were unsupervised and done under free-living conditions. During the closed-loop period, a model-predictive control algorithm directed insulin delivery, and prandial insulin delivery was calculated with a standard bolus wizard. The primary outcome was the proportion of time when sensor glucose concentration was in target range (3·9–10·0 mmol/L) over the 4 week study period. Analyses were by intention to treat. This study is registered withClinicalTrials.gov, numberNCT02727231, and is completed. Findings: Between March 21 and June 24, 2016, we recruited 31 participants, of whom 29 were randomised. One participant withdrew during the first closed-loop period because of dissatisfaction with study devices and glucose control. The proportion of time when sensor glucose concentration was in target range was 10·5 percentage points higher (95% CI 7·6–13·4; p<0·0001) during closed-loop delivery compared with usual pump therapy (65·6% [SD 8·1] when participants used usual pump therapy vs 76·2% [6·4] when they used closed-loop). Compared with usual pump therapy, closed-loop delivery also reduced the proportion of time spent in hypoglycaemia: the proportion of time with glucose concentration below 3·5 mmol/L was reduced by 65% (53–74, p<0·0001) and below 2·8 mmol/L by 76% (59–86, p<0·0001). No episodes of serious hypoglycaemia or other serious adverse events occurred. Interpretation: Use of day-and-night hybrid closed-loop insulin delivery under unsupervised, free-living conditions for 4 weeks in adults with type 1 diabetes and HbA1c below 7·5% is safe and well tolerated, improves glucose control, and reduces hypoglycaemia burden. Larger and longer studies are warranted. Funding: Swiss National Science Foundation (P1BEP3_165297 ), JDRF, UK National Institute for Health Research Cambridge Biomedical Research Centre, andWellcome Strategic Award (100574/Z/12/Z ). … (more)
- Is Part Of:
- Lancet. Volume 5:Issue 4(2017)
- Journal:
- Lancet
- Issue:
- Volume 5:Issue 4(2017)
- Issue Display:
- Volume 5, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 5
- Issue:
- 4
- Issue Sort Value:
- 2017-0005-0004-0000
- Page Start:
- 261
- Page End:
- 270
- Publication Date:
- 2017-04
- Subjects:
- Diabetes -- Periodicals
Endocrinology -- Periodicals
Endocrine glands -- Diseases -- Periodicals
616.4 - Journal URLs:
- http://www.sciencedirect.com/ ↗
- DOI:
- 10.1016/S2213-8587(17)30001-3 ↗
- Languages:
- English
- ISSNs:
- 2213-8587
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5146.080050
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8260.xml