Accuracy and mechanical performance of passivated and conventional fabricated 3-unit fixed dental prosthesis on multi-unit abutments. Issue 4 (October 2017)
- Record Type:
- Journal Article
- Title:
- Accuracy and mechanical performance of passivated and conventional fabricated 3-unit fixed dental prosthesis on multi-unit abutments. Issue 4 (October 2017)
- Main Title:
- Accuracy and mechanical performance of passivated and conventional fabricated 3-unit fixed dental prosthesis on multi-unit abutments
- Authors:
- Stimmelmayr, Michael
Groesser, Julian
Beuer, Florian
Erdelt, Kurt
Krennmair, Gerald
Sachs, Caroline
Edelhoff, Daniel
Güth, Jan-Frederik - Abstract:
- Abstract: Purpose: The aim of this study was to evaluate the fit and mechanical stability of conventional versus passive fitting 3-unit fixed dental prosthesis (FDP) screw-retained on implants. Methods: Twenty acrylic models, each with two embedded implants, were fabricated and functioned as patient-models. Impressions were taken and 20 all-ceramic FDPs were pre-fabricated on the plaster casts. Respectively 10 FDPs were fixed on the plaster casts (group 1) and on the patient-models for passive fitting (group 2). The fit of each FDP was checked on the patient-model by means of visual control (grades 1–10) and microscopic examination. Furthermore, specimens were artificially aged for possible prosthodontic failures, followed by a fracture strength test. Results: Group 2 [1.4 (±0.3)] showed significantly (p < 0.001) better results in the visual examination of the marginal fit compared to group 1 [6.3 (±2.4)]. The microscopic marginal misfit was 160 μm (±80 μm) at the abutment margin and 150 μm (±80 μm) at the axial wall of the abutment for group 1, respectively, 0 μm and 0 μm up to 17 μm for group 2 (p < 0.001). No failure of the FDPs could be observed during artificial aging in both groups. The fracture load showed no significant difference (p = 0.60) between group 1 [2583 N (±664 N)] and group 2 [2465 N (±238 N)]. Conclusions: Visual and microscopic examination detected huge differences in marginal fit between groups 1 and 2. However, no statistically verifiable differencesAbstract: Purpose: The aim of this study was to evaluate the fit and mechanical stability of conventional versus passive fitting 3-unit fixed dental prosthesis (FDP) screw-retained on implants. Methods: Twenty acrylic models, each with two embedded implants, were fabricated and functioned as patient-models. Impressions were taken and 20 all-ceramic FDPs were pre-fabricated on the plaster casts. Respectively 10 FDPs were fixed on the plaster casts (group 1) and on the patient-models for passive fitting (group 2). The fit of each FDP was checked on the patient-model by means of visual control (grades 1–10) and microscopic examination. Furthermore, specimens were artificially aged for possible prosthodontic failures, followed by a fracture strength test. Results: Group 2 [1.4 (±0.3)] showed significantly (p < 0.001) better results in the visual examination of the marginal fit compared to group 1 [6.3 (±2.4)]. The microscopic marginal misfit was 160 μm (±80 μm) at the abutment margin and 150 μm (±80 μm) at the axial wall of the abutment for group 1, respectively, 0 μm and 0 μm up to 17 μm for group 2 (p < 0.001). No failure of the FDPs could be observed during artificial aging in both groups. The fracture load showed no significant difference (p = 0.60) between group 1 [2583 N (±664 N)] and group 2 [2465 N (±238 N)]. Conclusions: Visual and microscopic examination detected huge differences in marginal fit between groups 1 and 2. However, no statistically verifiable differences could be detected in long-term stability of implant-supported FDPs irrespective of the fit. … (more)
- Is Part Of:
- Journal of prosthodontic research. Volume 61:Issue 4(2017)
- Journal:
- Journal of prosthodontic research
- Issue:
- Volume 61:Issue 4(2017)
- Issue Display:
- Volume 61, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 61
- Issue:
- 4
- Issue Sort Value:
- 2017-0061-0004-0000
- Page Start:
- 403
- Page End:
- 411
- Publication Date:
- 2017-10
- Subjects:
- Implant -- 3-unit FDP -- Passive fit -- Cyclic loading -- Fatigue testing
Prosthodontics -- Periodicals
Dentistry -- Periodicals
Prosthodontics -- Periodicals
Electronic journals
Computer network resources
617.6905 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18831958 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jpor.2016.12.011 ↗
- Languages:
- English
- ISSNs:
- 1883-1958
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5042.915000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8263.xml