Simultaneous determination of metolazone and valsartan in plasma by on-line SPE coupled with liquid chromatography/tandem mass spectrometry. Issue 5 (October 2017)
- Record Type:
- Journal Article
- Title:
- Simultaneous determination of metolazone and valsartan in plasma by on-line SPE coupled with liquid chromatography/tandem mass spectrometry. Issue 5 (October 2017)
- Main Title:
- Simultaneous determination of metolazone and valsartan in plasma by on-line SPE coupled with liquid chromatography/tandem mass spectrometry
- Authors:
- Zhou, Jiezhao
Chen, Meiling
Li, Ying
Yu, Fanglin
Cheng, Xiaohui
Yang, Yang
Liu, Yan
Xie, Xiangyang
Li, Zhiping
Zhang, Hui
Mei, Xingguo - Abstract:
- Combination of metolazone (0.5 mg) and valsartan (80 mg) has been verified as a promising therapy treatment for hypertension. In order to facilitate to pharmacokinetic research, it needs a method for the simultaneously determination of metolazone and valsartan in biological samples. However, there are no relative reports so far. In order to facilitate to pharmacokinetic research, an on-line solid phase extraction coupled with liquid chromatography-tandem mass spectrometry method for the simultaneous determination of metolazone and valsartan in beagle dog plasma was developed and validated in this study. An on-line solid phase extraction column Retain PEP Javelin (10 mm × 2.1 mm) was used to remove impurities in plasma samples. The metolazone, valsartan and internal standard (losartan) were separated on a Poroshell 120 SB-C18 column (4.6 mm × 50 mm × 2.7 µm) with a gradient elution procedure. Acidified acetonitrile/water mixture was used as a mobile phase. The selected multiple-reaction monitoring mode in positive ion was performed and the parent to the product transitions m/z 366/259, m/z 436.2/291 and m/z 423.4/207 were used to measure the metolazone, valsartan and losartan. The method was linear over the range of 0.1–100 ng/mL and 1–1000 ng/mL for metolazone and valsartan, respectively. This method was validated in terms of specificity, linearity, sensitivity, precision, accuracy, matrix effect, and stability and then successfully applied to pharmacokinetic studies of theCombination of metolazone (0.5 mg) and valsartan (80 mg) has been verified as a promising therapy treatment for hypertension. In order to facilitate to pharmacokinetic research, it needs a method for the simultaneously determination of metolazone and valsartan in biological samples. However, there are no relative reports so far. In order to facilitate to pharmacokinetic research, an on-line solid phase extraction coupled with liquid chromatography-tandem mass spectrometry method for the simultaneous determination of metolazone and valsartan in beagle dog plasma was developed and validated in this study. An on-line solid phase extraction column Retain PEP Javelin (10 mm × 2.1 mm) was used to remove impurities in plasma samples. The metolazone, valsartan and internal standard (losartan) were separated on a Poroshell 120 SB-C18 column (4.6 mm × 50 mm × 2.7 µm) with a gradient elution procedure. Acidified acetonitrile/water mixture was used as a mobile phase. The selected multiple-reaction monitoring mode in positive ion was performed and the parent to the product transitions m/z 366/259, m/z 436.2/291 and m/z 423.4/207 were used to measure the metolazone, valsartan and losartan. The method was linear over the range of 0.1–100 ng/mL and 1–1000 ng/mL for metolazone and valsartan, respectively. This method was validated in terms of specificity, linearity, sensitivity, precision, accuracy, matrix effect, and stability and then successfully applied to pharmacokinetic studies of the metolazone and valsartan combination tablets in beagle dogs. … (more)
- Is Part Of:
- European journal of mass spectrometry. Volume 23:Issue 5(2017)
- Journal:
- European journal of mass spectrometry
- Issue:
- Volume 23:Issue 5(2017)
- Issue Display:
- Volume 23, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 23
- Issue:
- 5
- Issue Sort Value:
- 2017-0023-0005-0000
- Page Start:
- 305
- Page End:
- 312
- Publication Date:
- 2017-10
- Subjects:
- On-line solid phase extraction -- liquid chromatography-tandem mass spectrometry -- metolazone -- valsartan -- dog plasma
Mass spectrometry -- Periodicals
Mass Spectrometry
Mass spectrometry
Periodicals
Periodicals
543.6505 - Journal URLs:
- http://www.impub.co.uk/ems.html ↗
http://journals.sagepub.com/toc/EMS/current ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1469066717716726 ↗
- Languages:
- English
- ISSNs:
- 1469-0667
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8281.xml