Impact of reduced k‐space acquisition on pathologic detectability for volumetric MR spectroscopic imaging. Issue 1 (4th April 2013)
- Record Type:
- Journal Article
- Title:
- Impact of reduced k‐space acquisition on pathologic detectability for volumetric MR spectroscopic imaging. Issue 1 (4th April 2013)
- Main Title:
- Impact of reduced k‐space acquisition on pathologic detectability for volumetric MR spectroscopic imaging
- Authors:
- Sabati, Mohammad
Zhan, Jiping
Govind, Varan
Arheart, Kristopher L.
Maudsley, Andrew A. - Abstract:
- Abstract : Purpose: To assess the impact of accelerated acquisitions on the spectral quality of volumetric magnetic resonance spectroscopic imaging (MRSI) and to evaluate their ability in detecting metabolic changes with mild injury. Materials and Methods: The implementation of a generalized autocalibrating partially parallel acquisition (GRAPPA) method for a high‐resolution whole‐brain echo planar SI (3D‐EPSI) sequence is first described and the spectral accuracy of the GRAPPA‐EPSI method is investigated using lobar and voxel‐based analyses for normal subjects and patients with mild traumatic brain injuries (mTBI). The performance of GRAPPA was compared with that of fully encoded EPSI for five datasets collected from normal subjects at the same scanning session, as well as on 45 scans (20 normal subjects and 25 mTBI patients) for which the reduced k ‐space sampling was simulated. For comparison, a central k ‐space lower‐resolution 3D‐EPSI acquisition was also simulated. Differences in individual metabolites and metabolite ratio distributions of the mTBI group relative to those of age‐matched control subjects were statistically evaluated using analyses divided into hemispheric brain lobes and tissue types. Results: GRAPPA‐EPSI with 16‐minute scan time yielded robust and similar results in terms of MRSI quantitation, spectral fitting, and accuracy with that of fully sampled 3D‐EPSI acquisitions and was more accurate than central k ‐space acquisition. Primary findings includedAbstract : Purpose: To assess the impact of accelerated acquisitions on the spectral quality of volumetric magnetic resonance spectroscopic imaging (MRSI) and to evaluate their ability in detecting metabolic changes with mild injury. Materials and Methods: The implementation of a generalized autocalibrating partially parallel acquisition (GRAPPA) method for a high‐resolution whole‐brain echo planar SI (3D‐EPSI) sequence is first described and the spectral accuracy of the GRAPPA‐EPSI method is investigated using lobar and voxel‐based analyses for normal subjects and patients with mild traumatic brain injuries (mTBI). The performance of GRAPPA was compared with that of fully encoded EPSI for five datasets collected from normal subjects at the same scanning session, as well as on 45 scans (20 normal subjects and 25 mTBI patients) for which the reduced k ‐space sampling was simulated. For comparison, a central k ‐space lower‐resolution 3D‐EPSI acquisition was also simulated. Differences in individual metabolites and metabolite ratio distributions of the mTBI group relative to those of age‐matched control subjects were statistically evaluated using analyses divided into hemispheric brain lobes and tissue types. Results: GRAPPA‐EPSI with 16‐minute scan time yielded robust and similar results in terms of MRSI quantitation, spectral fitting, and accuracy with that of fully sampled 3D‐EPSI acquisitions and was more accurate than central k ‐space acquisition. Primary findings included high correlations (accuracy of 92.6%) between the GRAPPA and fully sampled results. Conclusion: Although the reduced encoding method is associated with lower signal‐to‐noise ratio (SNR) that impacts the quality of spectral analysis, the use of the parallel imaging method can lead to the same diagnostic outcomes as the fully sampled data when using the sensitivity‐limited volumetric MRSI. J. Magn. Reson. Imaging 2014;39:224–234. © 2013 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 39:Issue 1(2014)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 39:Issue 1(2014)
- Issue Display:
- Volume 39, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 39
- Issue:
- 1
- Issue Sort Value:
- 2014-0039-0001-0000
- Page Start:
- 224
- Page End:
- 234
- Publication Date:
- 2013-04-04
- Subjects:
- MR spectroscopic imaging -- parallel imaging -- traumatic brain injury -- undersampled acquisition -- clinical equivalency
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24130 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8280.xml