Endothelial Function Assessed by Automatic Measurement of Enclosed Zone Flow‐Mediated Vasodilation Using an Oscillometric Method Is an Independent Predictor of Cardiovascular Events. Issue 12 (21st December 2016)
- Record Type:
- Journal Article
- Title:
- Endothelial Function Assessed by Automatic Measurement of Enclosed Zone Flow‐Mediated Vasodilation Using an Oscillometric Method Is an Independent Predictor of Cardiovascular Events. Issue 12 (21st December 2016)
- Main Title:
- Endothelial Function Assessed by Automatic Measurement of Enclosed Zone Flow‐Mediated Vasodilation Using an Oscillometric Method Is an Independent Predictor of Cardiovascular Events
- Authors:
- Morimoto, Haruka
Kajikawa, Masato
Oda, Nozomu
Idei, Naomi
Hirano, Harutoyo
Hida, Eisuke
Maruhashi, Tatsuya
Iwamoto, Yumiko
Kishimoto, Shinji
Matsui, Shogo
Aibara, Yoshiki
Hidaka, Takayuki
Kihara, Yasuki
Chayama, Kazuaki
Goto, Chikara
Noma, Kensuke
Nakashima, Ayumu
Ukawa, Teiji
Tsuji, Toshio
Higashi, Yukihito - Abstract:
- Abstract : Background: A new device for automatic measurement of flow‐mediated vasodilation (FMD) using an oscillometric method has been developed to solve technical problems of conventional FMD measurement. This device measures enclosed zone FMD (ezFMD). The purpose of this study was to evaluate the prognostic value of endothelial function assessed by ezFMD for future cardiovascular events. Methods and Results: We measured ezFMD in 272 participants who underwent health‐screening examinations. First, we investigated cross‐sectional associations between ezFMD and cardiovascular risk factors, and then we assessed the associations between ezFMD and first major cardiovascular events (death from cardiovascular causes, stroke, and coronary revascularization). Univariate regression analysis revealed that ezFMD was significantly correlated with age, triglycerides, glucose, smoking pack‐years, estimated glomerular filtration rate, high‐sensitivity C‐reactive protein, and Framingham risk score. During a median follow‐up period of 36.1 months (interquartile range 18.8–40.1 months), 12 participants died (6 from cardiovascular causes), 3 had stroke, 8 had coronary revascularization, and 10 were hospitalized for heart failure. There was no episode of acute coronary syndrome during the study period. Participants were divided into tertiles (low, intermediate, and high) based on ezFMD. Kaplan–Meier curves for first major cardiovascular events among the 3 groups were significantly different (Abstract : Background: A new device for automatic measurement of flow‐mediated vasodilation (FMD) using an oscillometric method has been developed to solve technical problems of conventional FMD measurement. This device measures enclosed zone FMD (ezFMD). The purpose of this study was to evaluate the prognostic value of endothelial function assessed by ezFMD for future cardiovascular events. Methods and Results: We measured ezFMD in 272 participants who underwent health‐screening examinations. First, we investigated cross‐sectional associations between ezFMD and cardiovascular risk factors, and then we assessed the associations between ezFMD and first major cardiovascular events (death from cardiovascular causes, stroke, and coronary revascularization). Univariate regression analysis revealed that ezFMD was significantly correlated with age, triglycerides, glucose, smoking pack‐years, estimated glomerular filtration rate, high‐sensitivity C‐reactive protein, and Framingham risk score. During a median follow‐up period of 36.1 months (interquartile range 18.8–40.1 months), 12 participants died (6 from cardiovascular causes), 3 had stroke, 8 had coronary revascularization, and 10 were hospitalized for heart failure. There was no episode of acute coronary syndrome during the study period. Participants were divided into tertiles (low, intermediate, and high) based on ezFMD. Kaplan–Meier curves for first major cardiovascular events among the 3 groups were significantly different ( P =0.004). After adjustment for cardiovascular risk factors, the low group was significantly associated with an increased risk of first major cardiovascular events compared with the high group (hazard ratio 6.47; 95% CI 1.09–125.55; P =0.038). Conclusions: These findings suggest that endothelial function assessed by ezFMD may be useful as a surrogate marker of future cardiovascular events. Clinical Trial Registration: URL:https://upload.umin.ac.jp . Unique identifier: UMIN000004902. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 5:Issue 12(2016)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 5:Issue 12(2016)
- Issue Display:
- Volume 5, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 5
- Issue:
- 12
- Issue Sort Value:
- 2016-0005-0012-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2016-12-21
- Subjects:
- atherosclerosis -- biomarker -- cardiovascular events -- endothelial function
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.116.004385 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8268.xml