Temporal changes in filtering-facepiece respirator fit. Issue 4 (2nd April 2016)
- Record Type:
- Journal Article
- Title:
- Temporal changes in filtering-facepiece respirator fit. Issue 4 (2nd April 2016)
- Main Title:
- Temporal changes in filtering-facepiece respirator fit
- Authors:
- Zhuang, Ziqing
Bergman, Michael
Brochu, Elizabeth
Palmiero, Andrew
Niezgoda, George
He, Xinjian
Roberge, Raymond
Shaffer, Ronald - Abstract:
- ABSTRACT: A three-year study examined changes in N95 filtering-facepiece respirator (FFR) fit at six-month intervals and the relationship between fit and changes in weight for 229 subjects. During each visit, subjects performed a total of nine fit tests using three samples of the same FFR model. Inward leakage and filter penetration were measured for each donned respirator to determine face seal leakage (FSL). A total of 195 subjects completed the second visit and 134 subjects completed all seven visits. Acceptable fit was defined as 90th percentile FSL ≤ 5% and at least one fit factor ≥ 100. An unacceptable fit was observed for 14, 10, 7, 12, 15, and 16% of subjects on Visits 2–7, respectively. The predicted risk of an unacceptable fit increased with increasing length of time between fit tests, from 10% at Year 1 to 20% at Year 2 and to 25% at Year 3. Twenty-four percent of subjects who lost ≥ 20 lb had an unacceptable fit; these percentages ranged from 7–17% for subjects with lower weight losses or any degree of weight gain. Results support the current OSHA requirement for annual fit testing and suggest that respirator users who lose more than 20 lb should be re-tested for respirator fit.
- Is Part Of:
- Journal of occupational and environmental hygiene. Volume 13:Issue 4(2016)
- Journal:
- Journal of occupational and environmental hygiene
- Issue:
- Volume 13:Issue 4(2016)
- Issue Display:
- Volume 13, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 13
- Issue:
- 4
- Issue Sort Value:
- 2016-0013-0004-0000
- Page Start:
- 265
- Page End:
- 274
- Publication Date:
- 2016-04-02
- Subjects:
- Fit change -- fit test -- frequency of fit test -- N95 filtering facepiece respirator -- respirators
Industrial hygiene -- Periodicals
Environmental health -- Periodicals
Medicine, Industrial -- Periodicals
Occupational Health -- Periodicals
Environmental Exposure -- Periodicals
Environmental Health -- Periodicals
Occupational Exposure -- Periodicals
Hygiène industrielle -- Périodiques
Hygiène du milieu -- Périodiques
Médecine du travail -- Périodiques
613.62 - Journal URLs:
- http://www.tandfonline.com/ ↗
- DOI:
- 10.1080/15459624.2015.1116692 ↗
- Languages:
- English
- ISSNs:
- 1545-9624
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5026.080500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8239.xml