Accuracy of Consumer Monitors for Estimating Energy Expenditure and Activity Type. Issue 2 (February 2017)
- Record Type:
- Journal Article
- Title:
- Accuracy of Consumer Monitors for Estimating Energy Expenditure and Activity Type. Issue 2 (February 2017)
- Main Title:
- Accuracy of Consumer Monitors for Estimating Energy Expenditure and Activity Type
- Authors:
- WOODMAN, JAMES A.
CROUTER, SCOTT E.
BASSETT, DAVID R.
FITZHUGH, EUGENE C.
BOYER, WILLIAM R. - Abstract:
- ABSTRACT: Introduction: Increasing use of consumer-based physical activity (PA) monitors necessitates that they are validated against criterion measures. Thus, the purpose of this study was to examine the accuracy of three consumer-based PA monitors for estimating energy expenditure (EE) and PA type during simulated free-living activities. Methods: Twenty-eight participants (mean ± SD: age, 25.5 ± 3.7 yr; body mass index, 24.9 ± 2.6 kg·m −2 ) completed 11 activities ranging from sedentary behaviors to vigorous intensities. Simultaneous measurements were made with an Oxycon portable calorimeter (criterion), a Basis Peak and Garmin Vivofit on the nondominant wrist, and three Withings Pulse devices (right hip, shirt collar, dominant wrist). Repeated-measures ANOVA were used to examine differences between measured and predicted EE. Intraclass correlation coefficients were calculated to determine reliability of EE predictions between Withings placements. Paired samples t tests were used to determine mean differences between observed minutes and Basis Peak predictions during walking, running, and cycling. Results: On average, the Basis Peak was within 8% of measured EE for the entire PA routine ( P > 0.05); however, there were large individual errors (95% prediction interval, −290.4 to +233.1 kcal). All other devices were significantly different from measured EE for the entire PA routine ( P < 0.05). For activity types, Basis Peak correctly identified ≥92% of actual minutes spentABSTRACT: Introduction: Increasing use of consumer-based physical activity (PA) monitors necessitates that they are validated against criterion measures. Thus, the purpose of this study was to examine the accuracy of three consumer-based PA monitors for estimating energy expenditure (EE) and PA type during simulated free-living activities. Methods: Twenty-eight participants (mean ± SD: age, 25.5 ± 3.7 yr; body mass index, 24.9 ± 2.6 kg·m −2 ) completed 11 activities ranging from sedentary behaviors to vigorous intensities. Simultaneous measurements were made with an Oxycon portable calorimeter (criterion), a Basis Peak and Garmin Vivofit on the nondominant wrist, and three Withings Pulse devices (right hip, shirt collar, dominant wrist). Repeated-measures ANOVA were used to examine differences between measured and predicted EE. Intraclass correlation coefficients were calculated to determine reliability of EE predictions between Withings placements. Paired samples t tests were used to determine mean differences between observed minutes and Basis Peak predictions during walking, running, and cycling. Results: On average, the Basis Peak was within 8% of measured EE for the entire PA routine ( P > 0.05); however, there were large individual errors (95% prediction interval, −290.4 to +233.1 kcal). All other devices were significantly different from measured EE for the entire PA routine ( P < 0.05). For activity types, Basis Peak correctly identified ≥92% of actual minutes spent walking and running ( P > 0.05), and 40.4% and 0% of overground and stationary cycling minutes, respectively ( P < 0.001). Conclusions: The Basis Peak was the only device that did not significantly differ from measured EE; however, it also had the largest individual errors. Additionally, the Basis Peak accurately predicted minutes spent walking and running, but not cycling. … (more)
- Is Part Of:
- Medicine and science in sports and exercise. Volume 49:Issue 2(2017)
- Journal:
- Medicine and science in sports and exercise
- Issue:
- Volume 49:Issue 2(2017)
- Issue Display:
- Volume 49, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 49
- Issue:
- 2
- Issue Sort Value:
- 2017-0049-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-02
- Subjects:
- ACCELEROMETRY -- PUBLIC HEALTH -- OXYGEN CONSUMPTION -- INDIRECT CALORIMETRY -- VALIDATION -- ACTIVITY RECOGNITION
Sports medicine -- Periodicals
Exercise -- Physiological aspects -- Periodicals
Exercise -- Health aspects -- Periodicals
612.044 - Journal URLs:
- http://journals.lww.com/acsm-msse/pages/default.aspx ↗
http://www.ms-se.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1249/MSS.0000000000001090 ↗
- Languages:
- English
- ISSNs:
- 0195-9131
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.006700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8252.xml