Real-Time Detection of Infusion Site Failures in a Closed-Loop Artificial Pancreas. (May 2018)
- Record Type:
- Journal Article
- Title:
- Real-Time Detection of Infusion Site Failures in a Closed-Loop Artificial Pancreas. (May 2018)
- Main Title:
- Real-Time Detection of Infusion Site Failures in a Closed-Loop Artificial Pancreas
- Authors:
- Howsmon, Daniel P.
Baysal, Nihat
Buckingham, Bruce A.
Forlenza, Gregory P.
Ly, Trang T.
Maahs, David M.
Marcal, Tatiana
Towers, Lindsey
Mauritzen, Eric
Deshpande, Sunil
Huyett, Lauren M.
Pinsker, Jordan E.
Gondhalekar, Ravi
Doyle, Francis J.
Dassau, Eyal
Hahn, Juergen
Bequette, B. Wayne - Abstract:
- Background: As evidence emerges that artificial pancreas systems improve clinical outcomes for patients with type 1 diabetes, the burden of this disease will hopefully begin to be alleviated for many patients and caregivers. However, reliance on automated insulin delivery potentially means patients will be slower to act when devices stop functioning appropriately. One such scenario involves an insulin infusion site failure, where the insulin that is recorded as delivered fails to affect the patient's glucose as expected. Alerting patients to these events in real time would potentially reduce hyperglycemia and ketosis associated with infusion site failures. Methods: An infusion site failure detection algorithm was deployed in a randomized crossover study with artificial pancreas and sensor-augmented pump arms in an outpatient setting. Each arm lasted two weeks. Nineteen participants wore infusion sets for up to 7 days. Clinicians contacted patients to confirm infusion site failures detected by the algorithm and instructed on set replacement if failure was confirmed. Results: In real time and under zone model predictive control, the infusion site failure detection algorithm achieved a sensitivity of 88.0% (n = 25) while issuing only 0.22 false positives per day, compared with a sensitivity of 73.3% (n = 15) and 0.27 false positives per day in the SAP arm (as indicated by retrospective analysis). No association between intervention strategy and duration of infusion sets wasBackground: As evidence emerges that artificial pancreas systems improve clinical outcomes for patients with type 1 diabetes, the burden of this disease will hopefully begin to be alleviated for many patients and caregivers. However, reliance on automated insulin delivery potentially means patients will be slower to act when devices stop functioning appropriately. One such scenario involves an insulin infusion site failure, where the insulin that is recorded as delivered fails to affect the patient's glucose as expected. Alerting patients to these events in real time would potentially reduce hyperglycemia and ketosis associated with infusion site failures. Methods: An infusion site failure detection algorithm was deployed in a randomized crossover study with artificial pancreas and sensor-augmented pump arms in an outpatient setting. Each arm lasted two weeks. Nineteen participants wore infusion sets for up to 7 days. Clinicians contacted patients to confirm infusion site failures detected by the algorithm and instructed on set replacement if failure was confirmed. Results: In real time and under zone model predictive control, the infusion site failure detection algorithm achieved a sensitivity of 88.0% (n = 25) while issuing only 0.22 false positives per day, compared with a sensitivity of 73.3% (n = 15) and 0.27 false positives per day in the SAP arm (as indicated by retrospective analysis). No association between intervention strategy and duration of infusion sets was observed ( P = .58). Conclusions: As patient burden is reduced by each generation of advanced diabetes technology, fault detection algorithms will help ensure that patients are alerted when they need to manually intervene. Clinical Trial Identifier: www.clinicaltrials.gov, NCT02773875 … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 12:Number 3(2018:May)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 12:Number 3(2018:May)
- Issue Display:
- Volume 12, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 12
- Issue:
- 3
- Issue Sort Value:
- 2018-0012-0003-0000
- Page Start:
- 599
- Page End:
- 607
- Publication Date:
- 2018-05
- Subjects:
- artificial pancreas -- fault detection -- infusion site failure -- model predictive control -- safety -- type 1 diabetes
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296818755173 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8236.xml