Interobserver Reproducibility of Percent Gleason Pattern 4 in Prostatic Adenocarcinoma on Prostate Biopsies. (December 2016)
- Record Type:
- Journal Article
- Title:
- Interobserver Reproducibility of Percent Gleason Pattern 4 in Prostatic Adenocarcinoma on Prostate Biopsies. (December 2016)
- Main Title:
- Interobserver Reproducibility of Percent Gleason Pattern 4 in Prostatic Adenocarcinoma on Prostate Biopsies
- Authors:
- Sadimin, Evita T.
Khani, Francesca
Diolombi, Mairo
Meliti, Abdelrazak
Epstein, Jonathan I. - Abstract:
- Abstract : In the WHO Classification of Tumours of the Urinary System and Male Genital Organs published in 2016, it was officially recommended that the percent of Gleason pattern 4 (GP4) be reported on pathology reports to better reflect the extent in Gleason score 7 tumors. In this study we assessed the reproducibility of reporting GP4 on prostate biopsies. We analyzed prospectively 422 cores containing GP4 from our consult cases over a period of 2.5 months. The percent pattern 4 was assigned to all the cases in 10% increments from 0% to 100% (with the addition of 5%) by 1 of 4 fellows in urological pathology and by the expert urological pathologist. Out of 422 cores, 32% were an exact match and 75% were within ±10% (weighted κ [κW ] value 0.67). Cases were further stratified on the basis of (1) scattered versus clustered GP4 in the background of Gleason pattern 3, (2) continuous versus discontinuous tumor involvement, (3) cribriform/glomeruloid pattern only versus poorly formed/fused pattern versus mixed cribriform and poorly formed/fused pattern, and (4) total tumor involvement of the core (⩽10% vs. >10% of the core). No significant differences were observed in the first 3 variables. However, in cases with ⩽10% involvement of the core, 61% were within ±10% (κW =0.50) compared with cases with >10% involvement of the core, in which 78% were within ±10% (κW =0.70). In summary, we showed that assessment of percent GP4 was relatively reproducible, with substantial agreementAbstract : In the WHO Classification of Tumours of the Urinary System and Male Genital Organs published in 2016, it was officially recommended that the percent of Gleason pattern 4 (GP4) be reported on pathology reports to better reflect the extent in Gleason score 7 tumors. In this study we assessed the reproducibility of reporting GP4 on prostate biopsies. We analyzed prospectively 422 cores containing GP4 from our consult cases over a period of 2.5 months. The percent pattern 4 was assigned to all the cases in 10% increments from 0% to 100% (with the addition of 5%) by 1 of 4 fellows in urological pathology and by the expert urological pathologist. Out of 422 cores, 32% were an exact match and 75% were within ±10% (weighted κ [κW ] value 0.67). Cases were further stratified on the basis of (1) scattered versus clustered GP4 in the background of Gleason pattern 3, (2) continuous versus discontinuous tumor involvement, (3) cribriform/glomeruloid pattern only versus poorly formed/fused pattern versus mixed cribriform and poorly formed/fused pattern, and (4) total tumor involvement of the core (⩽10% vs. >10% of the core). No significant differences were observed in the first 3 variables. However, in cases with ⩽10% involvement of the core, 61% were within ±10% (κW =0.50) compared with cases with >10% involvement of the core, in which 78% were within ±10% (κW =0.70). In summary, we showed that assessment of percent GP4 was relatively reproducible, with substantial agreement within ±10% in cases. However, with <10% involvement of the core, it was more difficult to assess in smaller foci, with only moderate agreement. Given that in a small focus only a few glands of a given pattern can markedly affect the percent GP4, consideration should be given to not recording percent GP4 in small foci of Gleason score 7 tumors on needle biopsy. … (more)
- Is Part Of:
- American journal of surgical pathology. Volume 40:Number 12(2016)
- Journal:
- American journal of surgical pathology
- Issue:
- Volume 40:Number 12(2016)
- Issue Display:
- Volume 40, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 40
- Issue:
- 12
- Issue Sort Value:
- 2016-0040-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-12
- Subjects:
- Gleason pattern 4 -- Gleason score 7 -- interobserver reproducibility -- prostatic adenocarcinoma
Pathology, Surgical -- Periodicals
617.0705 - Journal URLs:
- http://journals.lww.com/ajsp/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/PAS.0000000000000714 ↗
- Languages:
- English
- ISSNs:
- 0147-5185
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0838.520000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8245.xml