Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm: Optimization of Tube Voltage With Regard to Patient Size. Issue 2 (March 2017)
- Record Type:
- Journal Article
- Title:
- Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm: Optimization of Tube Voltage With Regard to Patient Size. Issue 2 (March 2017)
- Main Title:
- Submillisievert Computed Tomography of the Chest Using Model-Based Iterative Algorithm
- Authors:
- Deák, Zsuzsanna
Maertz, Friedrich
Meurer, Felix
Notohamiprodjo, Susan
Mueck, Fabian
Geyer, Lucas L.
Reiser, Maximilian F.
Wirth, Stefan - Abstract:
- Abstract : Objective: The aim of this study was to define optimal tube potential for soft tissue and vessel visualization in dose-reduced chest CT protocols using model-based iterative algorithm in average and overweight patients. Methods: Thirty-six patients receiving chest CT according to 3 protocols (120 kVp/noise index [NI], 60; 100 kVp/NI, 65; 80 kVp/NI, 70) were included in this prospective study, approved by the ethics committee. Patients' physical parameters and dose descriptors were recorded. Images were reconstructed with model-based algorithm. Two radiologists evaluated image quality and lesion conspicuity; the protocols were intraindividually compared with preceding control CT reconstructed with statistical algorithm (120 kVp/NI, 20). Mean and standard deviation of attenuation of the muscle and fat tissues and signal-to-noise ratio of the aorta were measured. Results: Diagnostic images (lesion conspicuity, 95%–100%) were acquired in average and overweight patients at 1.34, 1.02, and 1.08 mGy and at 3.41, 3.20, and 2.88 mGy at 120, 100, and 80 kVp, respectively. Data are given as CT dose index volume values. Conclusions: Model-based algorithm allows for submillisievert chest CT in average patients; the use of 100 kVp is recommended.
- Is Part Of:
- Journal of computer assisted tomography. Volume 41:Issue 2(2017)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 41:Issue 2(2017)
- Issue Display:
- Volume 41, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 41
- Issue:
- 2
- Issue Sort Value:
- 2017-0041-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-03
- Subjects:
- dose reduction -- chest CT -- model-based iterative reconstruction -- tube voltage -- effective diameter -- effective dose
Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000505 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8247.xml