Sleep disturbance in patients with an implantable cardioverter defibrillator: Prevalence, predictors and impact on health status. (June 2018)
- Record Type:
- Journal Article
- Title:
- Sleep disturbance in patients with an implantable cardioverter defibrillator: Prevalence, predictors and impact on health status. (June 2018)
- Main Title:
- Sleep disturbance in patients with an implantable cardioverter defibrillator: Prevalence, predictors and impact on health status
- Authors:
- Habibović, M
Mudde, L
Pedersen, SS
Schoormans, D
Widdershoven, J
Denollet, J - Abstract:
- Background: Sleep disturbances are highly prevalent in patients with cardiac diseases and associated with poor health outcomes. However, little is known about sleep disturbance in patients with an implantable cardioverter defibrillator. Aims: We examined the prevalence and predictors of sleep disturbance and the impact on perceived health status in a Dutch cohort of implantable cardioverter defibrillator patients. Methods: Patients ( n =195) enrolled in the Web-based distress program for implantable cardioverter defibrillator patients (WEBCARE) trial completed questionnaires at the time of implantable cardioverter defibrillator implantation, three, six and 12 months afterwards. Sleep disturbance was assessed with the corresponding item #3 of the Patient Health Questionnaire 9. Results: At baseline, 67% ( n =130) reported sleep disturbance (cut off ≥1). One year later, the prevalence was 57% ( n =112). Younger age (odds ratio=0.96, 95% confidence interval 0.92–0.99; p =0.012) and high negative affectivity/low social inhibition (odds ratio=4.47, 95% confidence interval 1.52–13.17; p =0.007) were associated with sleep disturbance at 12 months in adjusted analyses. Sleep disturbance was not associated with health status at 12 months. Charlson Comorbidity Index, anxiety, Type D personality and high negative affectivity/low social inhibition were associated with impaired health status at follow-up. Conclusions: Sleep disturbance was highly prevalent in patients with an implantableBackground: Sleep disturbances are highly prevalent in patients with cardiac diseases and associated with poor health outcomes. However, little is known about sleep disturbance in patients with an implantable cardioverter defibrillator. Aims: We examined the prevalence and predictors of sleep disturbance and the impact on perceived health status in a Dutch cohort of implantable cardioverter defibrillator patients. Methods: Patients ( n =195) enrolled in the Web-based distress program for implantable cardioverter defibrillator patients (WEBCARE) trial completed questionnaires at the time of implantable cardioverter defibrillator implantation, three, six and 12 months afterwards. Sleep disturbance was assessed with the corresponding item #3 of the Patient Health Questionnaire 9. Results: At baseline, 67% ( n =130) reported sleep disturbance (cut off ≥1). One year later, the prevalence was 57% ( n =112). Younger age (odds ratio=0.96, 95% confidence interval 0.92–0.99; p =0.012) and high negative affectivity/low social inhibition (odds ratio=4.47, 95% confidence interval 1.52–13.17; p =0.007) were associated with sleep disturbance at 12 months in adjusted analyses. Sleep disturbance was not associated with health status at 12 months. Charlson Comorbidity Index, anxiety, Type D personality and high negative affectivity/low social inhibition were associated with impaired health status at follow-up. Conclusions: Sleep disturbance was highly prevalent in patients with an implantable cardioverter defibrillator. Younger age and high negative affectivity predicted sleep disturbance 12 months post-implantation independent of other demographic, clinical, intervention and psychological covariates. Sleep disturbance was not associated with impaired health status at the 12-month follow-up. … (more)
- Is Part Of:
- European journal of cardiovascular nursing. Volume 17:Number 5(2018)
- Journal:
- European journal of cardiovascular nursing
- Issue:
- Volume 17:Number 5(2018)
- Issue Display:
- Volume 17, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 17
- Issue:
- 5
- Issue Sort Value:
- 2018-0017-0005-0000
- Page Start:
- 390
- Page End:
- 398
- Publication Date:
- 2018-06
- Subjects:
- Sleep disturbance -- implantable cardioverter defibrillator -- health status -- negative affectivity
Cardiovascular system -- Diseases -- Nursing -- Periodicals
Cardiovascular Diseases -- nursing -- Periodicals
Cardiology -- Periodicals
Nursing -- Periodicals
Vascular Diseases -- Periodicals
610.7369105 - Journal URLs:
- https://academic.oup.com/eurjcn/issue ↗
http://cnu.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://www.sciencedirect.com/science/journal/14745151 ↗ - DOI:
- 10.1177/1474515117748931 ↗
- Languages:
- English
- ISSNs:
- 1474-5151
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725660
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8217.xml