Improved PCR based methods for detecting C9orf72 hexanucleotide repeat expansions. Issue 4 (August 2016)
- Record Type:
- Journal Article
- Title:
- Improved PCR based methods for detecting C9orf72 hexanucleotide repeat expansions. Issue 4 (August 2016)
- Main Title:
- Improved PCR based methods for detecting C9orf72 hexanucleotide repeat expansions
- Authors:
- Cleary, Elaine M.
Pal, Suvankar
Azam, Tara
Moore, David J.
Swingler, Robert
Gorrie, George
Stephenson, Laura
Colville, Shuna
Chandran, Siddharthan
Porteous, Mary
Warner, Jon P. - Abstract:
- Abstract: Due to the GC-rich, repetitive nature of C9orf72 hexanucleotide repeat expansions, PCR based detection methods are challenging. Several limitations of PCR have been reported and overcoming these could help to define the pathogenic range. There is also a need to develop improved repeat-primed PCR assays which allow detection even in the presence of genomic variation around the repeat region. We have optimised PCR conditions for the C9orf72 hexanucleotide repeat expansion, using betaine as a co-solvent and specific cycling conditions, including slow ramping and a high denaturation temperature. We have developed a flanking assay, and repeat-primed PCR assays for both 3′ and 5′ ends of the repeat expansion, which when used together provide a robust strategy for detecting the presence or absence of expansions greater than ∼100 repeats, even in the presence of genomic variability at the 3′ end of the repeat. Using our assays, we have detected repeat expansions in 47/442 Scottish ALS patients. Furthermore, we recommend the combined use of these assays in a clinical diagnostic setting. Highlights: Flanking PCR across C9orf72 repeat expansions up to 900 repeats has been performed. RP-PCR assays described for both 3′ and 5′ ends of the C9orf72 repeat expansion. Robust detection of expansions by RP-PCR for mosaic samples. Limitations of RP-PCR described.
- Is Part Of:
- Molecular and cellular probes. Volume 30:Issue 4(2016)
- Journal:
- Molecular and cellular probes
- Issue:
- Volume 30:Issue 4(2016)
- Issue Display:
- Volume 30, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 4
- Issue Sort Value:
- 2016-0030-0004-0000
- Page Start:
- 218
- Page End:
- 224
- Publication Date:
- 2016-08
- Subjects:
- C9orf72 -- Repeat-primed PCR -- Amyotrophic lateral sclerosis -- Genetic testing
Molecular probes -- Diagnostic use -- Periodicals
Pathology, Cellular -- Technique -- Periodicals
Cell Biology -- Periodicals
Molecular Biology -- Periodicals
Sondes moléculaires -- Utilisation diagnostique -- Périodiques
Cytopathologie -- Technique -- Périodiques
572 - Journal URLs:
- http://www.sciencedirect.com/science/journal/08908508 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0890-8508;screen=info;ECOIP ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.mcp.2016.06.001 ↗
- Languages:
- English
- ISSNs:
- 0890-8508
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5900.761000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8195.xml