Nanoscale toughening mechanism of nacre tablet. (January 2016)
- Record Type:
- Journal Article
- Title:
- Nanoscale toughening mechanism of nacre tablet. (January 2016)
- Main Title:
- Nanoscale toughening mechanism of nacre tablet
- Authors:
- Zhang, Ning
Yang, Shengfeng
Xiong, Liming
Hong, Yu
Chen, Youping - Abstract:
- Abstract: Nacre has attracted widespread interest because its unique hierarchical structure, which is assembled by 95 wt% brittle aragonite and 5 wt% soft organic materials, leads to several orders of improvement in fracture toughness. Apart from the well proposed toughening mechanisms such as mineral bridges and tablets interlocks, the organic materials including biopolymers between tablets and proteins exist within a tablet can also potentially improve the toughness. In this work, we employ a novel approach combining steered molecular dynamics (SMD) and classical molecular dynamics (MD) to build a model of mineral–protein composite to mimic nacre tablet. The critical role of protein in improving the fracture toughness of nacre is investigated for the first time. MD simulations of single crystalline aragonite, polycrystalline aragonite and mineral–protein composite under uniaxial tensile loading are performed, and the obtained constitutive responses are compared with experimental measurements of nacre under tension. It is shown that the fracture toughness of mineral–protein composite is significantly larger than that of single crystalline or polycrystalline aragonite. Detailed atomic configuration analyses reveal that the fracture of individual computer model is governed by its unique failure mechanisms. Dislocation motion and phase transformation are observed during the failure of single crystalline aragonite. Polycrystalline aragonite fails by the inter-granular cleavage,Abstract: Nacre has attracted widespread interest because its unique hierarchical structure, which is assembled by 95 wt% brittle aragonite and 5 wt% soft organic materials, leads to several orders of improvement in fracture toughness. Apart from the well proposed toughening mechanisms such as mineral bridges and tablets interlocks, the organic materials including biopolymers between tablets and proteins exist within a tablet can also potentially improve the toughness. In this work, we employ a novel approach combining steered molecular dynamics (SMD) and classical molecular dynamics (MD) to build a model of mineral–protein composite to mimic nacre tablet. The critical role of protein in improving the fracture toughness of nacre is investigated for the first time. MD simulations of single crystalline aragonite, polycrystalline aragonite and mineral–protein composite under uniaxial tensile loading are performed, and the obtained constitutive responses are compared with experimental measurements of nacre under tension. It is shown that the fracture toughness of mineral–protein composite is significantly larger than that of single crystalline or polycrystalline aragonite. Detailed atomic configuration analyses reveal that the fracture of individual computer model is governed by its unique failure mechanisms. Dislocation motion and phase transformation are observed during the failure of single crystalline aragonite. Polycrystalline aragonite fails by the inter-granular cleavage, as well as phase transformation within grain. It is surprisingly noted that other than the stretching of protein chains on grain boundaries, intra-granular fracture is triggered in mineral–protein composites. Proteins serve as strong glue between the inorganic nanograins. It is believed that the strong electrostatic interaction between protein and aragonite nanograins, combined with the remarkable plastic ductility of protein lead to the intra-granular failure, which consequently enhance the fracture toughness of the whole specimen. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 53(2016)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 53(2016)
- Issue Display:
- Volume 53, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 53
- Issue:
- 2016
- Issue Sort Value:
- 2016-0053-2016-0000
- Page Start:
- 200
- Page End:
- 209
- Publication Date:
- 2016-01
- Subjects:
- Nacre tablet -- Toughening mechanism -- Protein–mineral interaction -- Molecular dynamics -- Aragonite -- Electrostatic interaction
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2015.08.020 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8191.xml