Development of a new corona discharge based ion source for high resolution time-of-flight chemical ionization mass spectrometer to measure gaseous H2SO4 and aerosol sulfate. (October 2015)
- Record Type:
- Journal Article
- Title:
- Development of a new corona discharge based ion source for high resolution time-of-flight chemical ionization mass spectrometer to measure gaseous H2SO4 and aerosol sulfate. (October 2015)
- Main Title:
- Development of a new corona discharge based ion source for high resolution time-of-flight chemical ionization mass spectrometer to measure gaseous H2SO4 and aerosol sulfate
- Authors:
- Zheng, Jun
Yang, Dongsen
Ma, Yan
Chen, Mindong
Cheng, Jin
Li, Shizheng
Wang, Ming - Abstract:
- Abstract: A new corona discharge (CD) based ion source was developed for a commercial high-resolution time-of-flight chemical ionization mass spectrometer (HRToF-CIMS) (Aerodyne Research Inc.) to measure both gaseous sulfuric acid (H2 SO4 ) and aerosol sulfate after thermal desorption. Nitrate core ions (NO3 − ) were used as reagent ions and were generated by a negative discharge in zero air followed by addition of excess nitrogen dioxide (NO2 ) to convert primary ions and hydroxyl radicals (OH) into NO3 − ions and nitric acid (HNO3 ). The CD-HRToF-CIMS showed no detectable interference from hundreds parts per billion by volume (ppbv) of sulfur dioxide (SO2 ). Unlike the atmospheric pressure ionization (API) ToF-CIMS, the CD ion source was integrated onto the ion–molecule reaction (IMR) chamber and which made it possible to measure aerosol sulfate by coupling to a filter inlet for gases and aerosols (FIGAERO). Moreover, compared with a quadrupole-based mass spectrometer, the desired HSO4 − signal was detected by its exact mass of m / z 96.960, which was well resolved from the potential interferences of HCO3 − ⋅(H2 O)2 ( m / z 97.014) and O − ⋅H2 O⋅HNO3 ( m / z 97.002). In this work, using laboratory-generated standards the CD-HRToF-CIMS was demonstrated to be able to detect as low as 3.1 × 10 5 molecules cm −3 gaseous H2 SO4 and 0.5 μg m −3 ammonium sulfate based on 10-s integration time and two times of the baseline noise. The CD ion source had the advantages of low costAbstract: A new corona discharge (CD) based ion source was developed for a commercial high-resolution time-of-flight chemical ionization mass spectrometer (HRToF-CIMS) (Aerodyne Research Inc.) to measure both gaseous sulfuric acid (H2 SO4 ) and aerosol sulfate after thermal desorption. Nitrate core ions (NO3 − ) were used as reagent ions and were generated by a negative discharge in zero air followed by addition of excess nitrogen dioxide (NO2 ) to convert primary ions and hydroxyl radicals (OH) into NO3 − ions and nitric acid (HNO3 ). The CD-HRToF-CIMS showed no detectable interference from hundreds parts per billion by volume (ppbv) of sulfur dioxide (SO2 ). Unlike the atmospheric pressure ionization (API) ToF-CIMS, the CD ion source was integrated onto the ion–molecule reaction (IMR) chamber and which made it possible to measure aerosol sulfate by coupling to a filter inlet for gases and aerosols (FIGAERO). Moreover, compared with a quadrupole-based mass spectrometer, the desired HSO4 − signal was detected by its exact mass of m / z 96.960, which was well resolved from the potential interferences of HCO3 − ⋅(H2 O)2 ( m / z 97.014) and O − ⋅H2 O⋅HNO3 ( m / z 97.002). In this work, using laboratory-generated standards the CD-HRToF-CIMS was demonstrated to be able to detect as low as 3.1 × 10 5 molecules cm −3 gaseous H2 SO4 and 0.5 μg m −3 ammonium sulfate based on 10-s integration time and two times of the baseline noise. The CD ion source had the advantages of low cost and a simple but robust structure. Since the system was non-radioactive and did not require corrosive HNO3 gas, it can be readily field deployed. The CD-HRToF-CIMS can be a powerful tool for both field and laboratory studies of aerosol formation mechanism and the chemical processes that were critical to understand the evolution of aerosols in the atmosphere. Highlights: A new corona discharge ion source was developed for the Aerodyne HRToF-CIMS. The CD ion source was non-radioactive and non-corrosive. Both gaseous H2 SO4 and aerosol sulfate can be detected by the CD-HRToF-CIMS. … (more)
- Is Part Of:
- Atmospheric environment. Volume 119(2015)
- Journal:
- Atmospheric environment
- Issue:
- Volume 119(2015)
- Issue Display:
- Volume 119, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 119
- Issue:
- 2015
- Issue Sort Value:
- 2015-0119-2015-0000
- Page Start:
- 167
- Page End:
- 173
- Publication Date:
- 2015-10
- Subjects:
- Sulfuric acid -- Sulfate -- Corona discharge -- HRToF-CIMS -- Hydroxyl radicals
Air -- Pollution -- Periodicals
Air -- Pollution -- Meteorological aspects -- Periodicals
551.51 - Journal URLs:
- http://www.sciencedirect.com/web-editions/journal/13522310 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.atmosenv.2015.08.028 ↗
- Languages:
- English
- ISSNs:
- 1352-2310
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1767.120000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8187.xml