Simultaneous Visualization of Hydrogen Peroxide and Water Concentrations Using Photofragmentation Laser-Induced Fluorescence. Issue 9 (September 2017)
- Record Type:
- Journal Article
- Title:
- Simultaneous Visualization of Hydrogen Peroxide and Water Concentrations Using Photofragmentation Laser-Induced Fluorescence. Issue 9 (September 2017)
- Main Title:
- Simultaneous Visualization of Hydrogen Peroxide and Water Concentrations Using Photofragmentation Laser-Induced Fluorescence
- Authors:
- Larsson, Kajsa
Aldén, Marcus
Bood, Joakim - Abstract:
- A concept based on photofragmentation laser-induced fluorescence (PFLIF) is for the first time demonstrated for simultaneous detection of hydrogen peroxide (H2 O2 ) and water (H2 O) vapor in various mixtures containing the two constituents in a bath of argon gas. A photolysis laser pulse at 248 nm dissociates H2 O2 into OH fragments, whereupon a probe pulse, delayed 100 ns and tuned to an absorption line in the A 2 Σ + (v = 1) ← X 2 Π(v = 0) band of OH near 282 nm, induces fluorescence. The total OH fluorescence reflects the H2 O2 concentration, while its spectral shape is utilized to determine the H2 O concentration via a model predicting the ratio between the fluorescence intensities of the A 2 Σ + (v = 1) → X 2 Π(v = 1) and the A 2 Σ + (v = 0) → X 2 Π(v = 0) bands. The H2 O detection scheme requires that the bath gas has a collisional cross-section with OH(A) that is significantly lower than that of H2 O, which is the case for argon. Spectrally dispersed OH fluorescence spectra were recorded for five different H2 O2 /H2 O/Ar mixtures; the H2 O2 concentration in the range of 30–500 ppm and the H2 O concentration in the range of 0–3%. Fluorescence intensity ratios predicted by the model for these mixtures agree very well with corresponding experimental data, which thus validates the model. The concept was also demonstrated for two-dimensional imaging, using two intensified charge-coupled device (CCD) cameras for signal detection. Water content was here sensed through theA concept based on photofragmentation laser-induced fluorescence (PFLIF) is for the first time demonstrated for simultaneous detection of hydrogen peroxide (H2 O2 ) and water (H2 O) vapor in various mixtures containing the two constituents in a bath of argon gas. A photolysis laser pulse at 248 nm dissociates H2 O2 into OH fragments, whereupon a probe pulse, delayed 100 ns and tuned to an absorption line in the A 2 Σ + (v = 1) ← X 2 Π(v = 0) band of OH near 282 nm, induces fluorescence. The total OH fluorescence reflects the H2 O2 concentration, while its spectral shape is utilized to determine the H2 O concentration via a model predicting the ratio between the fluorescence intensities of the A 2 Σ + (v = 1) → X 2 Π(v = 1) and the A 2 Σ + (v = 0) → X 2 Π(v = 0) bands. The H2 O detection scheme requires that the bath gas has a collisional cross-section with OH(A) that is significantly lower than that of H2 O, which is the case for argon. Spectrally dispersed OH fluorescence spectra were recorded for five different H2 O2 /H2 O/Ar mixtures; the H2 O2 concentration in the range of 30–500 ppm and the H2 O concentration in the range of 0–3%. Fluorescence intensity ratios predicted by the model for these mixtures agree very well with corresponding experimental data, which thus validates the model. The concept was also demonstrated for two-dimensional imaging, using two intensified charge-coupled device (CCD) cameras for signal detection. Water content was here sensed through the different temporal characteristics of the two fluorescence bands by triggering the two cameras so that one captures the total OH fluorescence while the other one captures only the early part, which mainly stems from A 2 Σ + (v = 1) → X 2 Π(v = 1) fluorescence. Hence, the H2 O2 concentration is reflected by the image of the camera recording the total OH fluorescence, whereas H2 O concentration is extracted from the ratio between the two camera images. Quantification of the concentrations was carried out based on calibration measurements performed in known mixtures of H2 O2 (30–500 ppm) and H2 O (0–3%) in bulk argon. The detection limits for single-shot imaging are estimated to be 20 ppm for H2 O2 and 0.05% for H2 O. The authors believe that the concept provides a valuable asset in, for example, pharmaceutical or aseptic food packaging applications, where H2 O2 /H2 O vapor is routinely used for sterilization. … (more)
- Is Part Of:
- Applied spectroscopy. Volume 71:Issue 9(2017)
- Journal:
- Applied spectroscopy
- Issue:
- Volume 71:Issue 9(2017)
- Issue Display:
- Volume 71, Issue 9 (2017)
- Year:
- 2017
- Volume:
- 71
- Issue:
- 9
- Issue Sort Value:
- 2017-0071-0009-0000
- Page Start:
- 2118
- Page End:
- 2127
- Publication Date:
- 2017-09
- Subjects:
- Photofragmentation -- laser-induced fluorescence -- imaging -- hydrogen peroxide -- water
Spectrum analysis -- Periodicals
543.505 - Journal URLs:
- http://asp.sagepub.com/ ↗
http://www.ingentaconnect.com/content/sas/sas ↗
http://www.uk.sagepub.com/home.nav ↗
http://firstsearch.oclc.org/journal=0003-7028;screen=info;ECOIP ↗ - DOI:
- 10.1177/0003702817702386 ↗
- Languages:
- English
- ISSNs:
- 0003-7028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8195.xml