Core needle biopsy of thyroid nodules: outcomes and safety from a large single-center single-operator study. (August 2018)
- Record Type:
- Journal Article
- Title:
- Core needle biopsy of thyroid nodules: outcomes and safety from a large single-center single-operator study. (August 2018)
- Main Title:
- Core needle biopsy of thyroid nodules: outcomes and safety from a large single-center single-operator study
- Authors:
- Choe, Jooae
Baek, Jung Hwan
Park, Hye Sun
Choi, Young Jun
Lee, Jeong Hyun - Abstract:
- Background: There currently remains a debate over the use of core needle biopsy (CNB) or fine needle aspiration (FNA) for diagnosis of thyroid nodules. The major drawbacks of previous CNB studies include heterogeneity of the study population, variable techniques, devices, and operator experience affecting the outcome of the procedure. Purpose: To assess the diagnostic performance and safety of CNB of thyroid nodules performed by a single experienced operator in consecutive patients. Material and Methods: From January 2012 to December 2012, 538 thyroid nodules that underwent CNB were retrospectively evaluated. All CNB procedures were performed by a single operator with 18 years of experience. The histopathology of the surgical specimens was considered as the standard reference for malignancy. A final diagnosis of benignity was made by surgery, one benign lesion on FNA and/or CNB with no change on follow-up examinations (>1 year) or benign lesion on ≥2 FNA and/or CNB. The diagnostic performance, incidence of technical failure, unnecessary surgery, and complication were evaluated. Results: The diagnostic accuracy, sensitivity, and specificity of CNB for malignancy were 92.0%, 85.3%, and 100%, respectively. The non-diagnostic result rate of CNB was 4.8% (26/538) and the inconclusive result rate was 24.3% (131/538). The incidence of technical failure was 0.6% (3/541) and unnecessary surgery was 0.6%. The complication rate was 0.2%, without life-threatening complications. TheBackground: There currently remains a debate over the use of core needle biopsy (CNB) or fine needle aspiration (FNA) for diagnosis of thyroid nodules. The major drawbacks of previous CNB studies include heterogeneity of the study population, variable techniques, devices, and operator experience affecting the outcome of the procedure. Purpose: To assess the diagnostic performance and safety of CNB of thyroid nodules performed by a single experienced operator in consecutive patients. Material and Methods: From January 2012 to December 2012, 538 thyroid nodules that underwent CNB were retrospectively evaluated. All CNB procedures were performed by a single operator with 18 years of experience. The histopathology of the surgical specimens was considered as the standard reference for malignancy. A final diagnosis of benignity was made by surgery, one benign lesion on FNA and/or CNB with no change on follow-up examinations (>1 year) or benign lesion on ≥2 FNA and/or CNB. The diagnostic performance, incidence of technical failure, unnecessary surgery, and complication were evaluated. Results: The diagnostic accuracy, sensitivity, and specificity of CNB for malignancy were 92.0%, 85.3%, and 100%, respectively. The non-diagnostic result rate of CNB was 4.8% (26/538) and the inconclusive result rate was 24.3% (131/538). The incidence of technical failure was 0.6% (3/541) and unnecessary surgery was 0.6%. The complication rate was 0.2%, without life-threatening complications. The sensitivity, specificity, and accuracy were 85.3% (156/183), 100.0% (154/154), and 92.0% (310/337), respectively. Conclusion: CNB shows a high diagnostic performance for detection of thyroid malignancy and follicular neoplasm, with low rates of technical failure and complications. … (more)
- Is Part Of:
- Acta radiologica. Volume 59:Number 8(2018:Oct.)
- Journal:
- Acta radiologica
- Issue:
- Volume 59:Number 8(2018:Oct.)
- Issue Display:
- Volume 59, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 59
- Issue:
- 8
- Issue Sort Value:
- 2018-0059-0008-0000
- Page Start:
- 924
- Page End:
- 931
- Publication Date:
- 2018-08
- Subjects:
- Thyroid -- thyroid cancer -- thyroid malignancy -- core needle biopsy -- fine needle aspiration
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185117741916 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8170.xml