High-pitch dual-source paranasal sinus CT in agitated patients with maxillofacial trauma: analysis of image quality, motion artifacts, and dose aspects. (August 2018)
- Record Type:
- Journal Article
- Title:
- High-pitch dual-source paranasal sinus CT in agitated patients with maxillofacial trauma: analysis of image quality, motion artifacts, and dose aspects. (August 2018)
- Main Title:
- High-pitch dual-source paranasal sinus CT in agitated patients with maxillofacial trauma: analysis of image quality, motion artifacts, and dose aspects
- Authors:
- Frellesen, Claudia
Wichmann, Julian L
Tischendorf, Patricia
Scholtz, Jan-Erik
Beeres, Martin
Vogl, Thomas J
Bauer, Ralf W - Abstract:
- Background: Image quality benefits from high-pitch scanning in agitated patients by reducing acquisition time. Purpose: To compare image quality and exposure parameters in patients with maxillofacial trauma on second- and third-generation dual-source computed tomography (DSCT). Material and Methods: Four groups were compared. Group 1 was examined on second-generation DSCT (120 kV/50 mAs, pitch 3.0). The other three groups were examined on third-generation DSCT. Group 2 was scanned with 120 kV/50 mAs, pitch 2.2. Automated exposure control (AEC) was used in group 3 and group 4 with pitch factors of 2.2 and 3.0, respectively. Images of third-generation DSCT were reconstructed with iterative reconstruction (IR), of second-generation DSCT with filtered back-projection. CTDIvol, acquisition time, and image quality were compared. Results: Thirty patients were included in each group. Average CTDIvol (2.76 ± 0.00 mGy, 2.66 ± 0.00 mGy, 0.74 ± 0.23 mGy, and 0.75 ± 0.17 mGy) was significantly lower on third-generation DSCT with AEC ( P < 0.001). Subjective image quality was rated worst in group 4 due to strong high-pitch artifacts, while in the remaining three groups it was rated good or very good with good inter-observer agreement (k > 0.64). Average acquisition time was significantly shorter with third-generation DSCT (0.47 s, 0.36 s, 0.38 s, 0.30 s; P < 0.001). Conclusion: Third-generation DSCT yields faster acquisition times and substantial dose reduction with AEC. A pitch of 2.2Background: Image quality benefits from high-pitch scanning in agitated patients by reducing acquisition time. Purpose: To compare image quality and exposure parameters in patients with maxillofacial trauma on second- and third-generation dual-source computed tomography (DSCT). Material and Methods: Four groups were compared. Group 1 was examined on second-generation DSCT (120 kV/50 mAs, pitch 3.0). The other three groups were examined on third-generation DSCT. Group 2 was scanned with 120 kV/50 mAs, pitch 2.2. Automated exposure control (AEC) was used in group 3 and group 4 with pitch factors of 2.2 and 3.0, respectively. Images of third-generation DSCT were reconstructed with iterative reconstruction (IR), of second-generation DSCT with filtered back-projection. CTDIvol, acquisition time, and image quality were compared. Results: Thirty patients were included in each group. Average CTDIvol (2.76 ± 0.00 mGy, 2.66 ± 0.00 mGy, 0.74 ± 0.23 mGy, and 0.75 ± 0.17 mGy) was significantly lower on third-generation DSCT with AEC ( P < 0.001). Subjective image quality was rated worst in group 4 due to strong high-pitch artifacts, while in the remaining three groups it was rated good or very good with good inter-observer agreement (k > 0.64). Average acquisition time was significantly shorter with third-generation DSCT (0.47 s, 0.36 s, 0.38 s, 0.30 s; P < 0.001). Conclusion: Third-generation DSCT yields faster acquisition times and substantial dose reduction with AEC. A pitch of 2.2 should be preferred, as it results in fewer artifacts. If AEC is used, latest IR ensures that diagnostic image quality is guaranteed. … (more)
- Is Part Of:
- Acta radiologica. Volume 59:Number 8(2018:Oct.)
- Journal:
- Acta radiologica
- Issue:
- Volume 59:Number 8(2018:Oct.)
- Issue Display:
- Volume 59, Issue 8 (2018)
- Year:
- 2018
- Volume:
- 59
- Issue:
- 8
- Issue Sort Value:
- 2018-0059-0008-0000
- Page Start:
- 909
- Page End:
- 916
- Publication Date:
- 2018-08
- Subjects:
- Computed tomography (CT) -- high-pitch CT -- dual-source CT -- paranasal sinus -- maxillofacial trauma -- dose reduction
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185117740931 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8170.xml