Diagnostic performance of CT-guided percutaneous transthoracic core needle biopsy using low tube voltage (100 kVp): comparison with conventional tube voltage (120 kVp). (April 2018)
- Record Type:
- Journal Article
- Title:
- Diagnostic performance of CT-guided percutaneous transthoracic core needle biopsy using low tube voltage (100 kVp): comparison with conventional tube voltage (120 kVp). (April 2018)
- Main Title:
- Diagnostic performance of CT-guided percutaneous transthoracic core needle biopsy using low tube voltage (100 kVp): comparison with conventional tube voltage (120 kVp)
- Authors:
- Lee, Han Na
Lee, Sang Min
Choe, Jooae
Lee, Sang Min
Chae, Eun Jin
Do, Kyung-Hyun
Seo, Joon Beom - Abstract:
- Background: Computed tomography (CT)-guided percutaneous transthoracic core needle biopsy (PTNB) is typically performed at 120 kVp tube voltage. However, there is no study that has demonstrated diagnostic performance including ground-glass nodules and radiation dose reduction at lower tube voltage in large population. Purpose: To retrospectively compare the diagnostic performance and radiation dose between 100 kVp and 120 kVp during CT-guided PTNB. Material and Methods: This study included 393 PTNBs performed in 385 patients (Group I; 120 kVp) from March 2011 to September 2011 and 1368 PTNBs performed in 1318 patients (Group II; 100 kVp) from October 2011 to December 2013. The patients underwent CT-guided PTNB with the coaxial technique. Diagnostic performance, complication rate, and radiation dose were compared between two groups. Results: Technical success was achieved in 391 of 393 PTNBs (99.5%) in Group I and in 1344 of 1368 PTNBs (98.2%) in Group II ( P = 0.09). The diagnostic accuracies for pulmonary lesions were not significantly different between two groups (97.1% [362/373] versus 96.2% [1202/1249], P = 0.458). Complication rate showed no significant differences between two groups in terms of pneumothorax (19.7% [77/391] versus 19.4% [261/1344], P = 0.904) and hemoptysis (2.3% [9/391] versus 3.2% [43/1344], P = 0.360). Among patients who developed pneumothorax, three patients (3.9%, 3/77) in Group I and eight patients (3.1%, 8/261) in Group II required treatmentBackground: Computed tomography (CT)-guided percutaneous transthoracic core needle biopsy (PTNB) is typically performed at 120 kVp tube voltage. However, there is no study that has demonstrated diagnostic performance including ground-glass nodules and radiation dose reduction at lower tube voltage in large population. Purpose: To retrospectively compare the diagnostic performance and radiation dose between 100 kVp and 120 kVp during CT-guided PTNB. Material and Methods: This study included 393 PTNBs performed in 385 patients (Group I; 120 kVp) from March 2011 to September 2011 and 1368 PTNBs performed in 1318 patients (Group II; 100 kVp) from October 2011 to December 2013. The patients underwent CT-guided PTNB with the coaxial technique. Diagnostic performance, complication rate, and radiation dose were compared between two groups. Results: Technical success was achieved in 391 of 393 PTNBs (99.5%) in Group I and in 1344 of 1368 PTNBs (98.2%) in Group II ( P = 0.09). The diagnostic accuracies for pulmonary lesions were not significantly different between two groups (97.1% [362/373] versus 96.2% [1202/1249], P = 0.458). Complication rate showed no significant differences between two groups in terms of pneumothorax (19.7% [77/391] versus 19.4% [261/1344], P = 0.904) and hemoptysis (2.3% [9/391] versus 3.2% [43/1344], P = 0.360). Among patients who developed pneumothorax, three patients (3.9%, 3/77) in Group I and eight patients (3.1%, 8/261) in Group II required treatment with drainage catheter. Nobody needed further treatment for hemoptysis in the two groups. The mean radiation dose was 1.5 ± 1.9 mSv in Group I and 0.7 ± 0.3 mSv in Group II ( P < 0.001). Conclusion: The 100-kVp protocol for CT-guided PTNB showed significant benefit of radiation dose reduction while maintaining high diagnostic accuracy and safety. … (more)
- Is Part Of:
- Acta radiologica. Volume 59:Number 4(2018:May)
- Journal:
- Acta radiologica
- Issue:
- Volume 59:Number 4(2018:May)
- Issue Display:
- Volume 59, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 59
- Issue:
- 4
- Issue Sort Value:
- 2018-0059-0004-0000
- Page Start:
- 425
- Page End:
- 433
- Publication Date:
- 2018-04
- Subjects:
- Needle biopsy -- computed tomography (CT) -- lung -- radiation exposure
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185117719589 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8159.xml