Fourteen Day In Vivo Testing of a Compliant Thoracic Artificial Lung. Issue 5 (September 2017)
- Record Type:
- Journal Article
- Title:
- Fourteen Day In Vivo Testing of a Compliant Thoracic Artificial Lung. Issue 5 (September 2017)
- Main Title:
- Fourteen Day In Vivo Testing of a Compliant Thoracic Artificial Lung
- Authors:
- Skoog, David J.
Pohlmann, Joshua R.
Demos, David S.
Scipione, Christopher N.
Iyengar, Amit
Schewe, Rebecca E.
Suhaib, Ahmed B.
Koch, Kelly L.
Cook, Keith E. - Abstract:
- Abstract : The compliant thoracic artificial lung (cTAL) has been studied in acute in vivo and in vitro experiments. The cTAL's long-term function and potential use as a bridge to lung transplantation are assessed presently. The cTAL without anticoagulant coatings was attached to sheep (n = 5) via the pulmonary artery and left atrium for 14 days. Systemic heparin anticoagulation was used. Compliant thoracic artificial lung resistance, cTAL gas exchange, hematologic parameters, and organ function were recorded. Two sheep were euthanized for nondevice-related issues. The cTAL's resistance averaged 1.04 ± 0.05 mmHg/(L/min) with no statistically significant increases. The cTAL transferred 180 ± 8 ml/min of oxygen with 3.18 ± 0.05 L/min of blood flow. Except for transient surgical effects, organ function markers were largely unchanged. Necropsies revealed pulmonary edema and atelectasis but no other derangements. Hemoglobin levels dropped with device attachment but remained steady at 9.0 ± 0.1 g/dl thereafter. In a 14 day experiment, the cTAL without anticoagulant coatings exhibited minimal clot formation. Sheep physiology was largely unchanged except for device attachment-related hemodilution. This suggests that patients treated with the cTAL should not require multiple blood transfusions. Once tested with anticoagulant coatings and plasma resistant gas exchange fiber, the cTAL could serve as a bridge to transplantation.
- Is Part Of:
- ASAIO journal. Volume 63:Issue 5(2017)
- Journal:
- ASAIO journal
- Issue:
- Volume 63:Issue 5(2017)
- Issue Display:
- Volume 63, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 63
- Issue:
- 5
- Issue Sort Value:
- 2017-0063-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-09
- Subjects:
- artificial lung -- ECMO -- bridge to lung transplantation -- destination therapy
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000000627 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8158.xml