Comparison of postoperative ultrasound criteria to predict unassisted use of arteriovenous fistulas for hemodialysis. Issue 2 (March 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of postoperative ultrasound criteria to predict unassisted use of arteriovenous fistulas for hemodialysis. Issue 2 (March 2018)
- Main Title:
- Comparison of postoperative ultrasound criteria to predict unassisted use of arteriovenous fistulas for hemodialysis
- Authors:
- Lee, Timmy
Magill, Missy
Burke, Steven K.
Blair, Andrew T.
Robbin, Michelle L.
Allon, Michael - Abstract:
- Introduction: Arteriovenous fistulas (AVF) frequently fail to mature. Postoperative ultrasounds provide objective measurements to predict unassisted AVF use for hemodialysis (unassisted use) and guide interventions to salvage nonmaturing AVFs. The optimal ultrasound criteria to assess AVF maturation are uncertain. We analyzed data from a multicenter, randomized, controlled, clinical trial to compare 2 published ultrasound maturation criteria used to predict unassisted AVF use for hemodialysis. Methods: We retrospectively analyzed prospective data on 105 patients undergoing new AVF creation, who underwent standardized postoperative ultrasounds at 6 and 12 weeks to measure AVF diameter and blood flow. Unassisted AVF use was defined as successful cannulation for ≥90 days without requiring prior surgical or percutaneous interventions. Two ultrasound criteria were assessed: (i) National Kidney Foundation (NKF) Kidney Disease Outcome Quality Initiative criteria: AVF outflow vein lumen diameter ≥6 mm and blood flow ≥600 mL/min; and (ii) University of Alabama at Birmingham (UAB) criteria: AVF outflow vein lumen diameter ≥4 mm and blood flow ≥500 mL/min. Performance characteristics were calculated for both criteria. Results: Compared to the NKF criteria, the UAB criteria had a higher sensitivity (89 vs.68%), but a lower specificity (42 vs. 70%) for unassisted AVF use. For radiocephalic AVFs, the UAB criteria had higher sensitivity (86 vs. 46%) and lower specificity (58 vs. 83%). ForIntroduction: Arteriovenous fistulas (AVF) frequently fail to mature. Postoperative ultrasounds provide objective measurements to predict unassisted AVF use for hemodialysis (unassisted use) and guide interventions to salvage nonmaturing AVFs. The optimal ultrasound criteria to assess AVF maturation are uncertain. We analyzed data from a multicenter, randomized, controlled, clinical trial to compare 2 published ultrasound maturation criteria used to predict unassisted AVF use for hemodialysis. Methods: We retrospectively analyzed prospective data on 105 patients undergoing new AVF creation, who underwent standardized postoperative ultrasounds at 6 and 12 weeks to measure AVF diameter and blood flow. Unassisted AVF use was defined as successful cannulation for ≥90 days without requiring prior surgical or percutaneous interventions. Two ultrasound criteria were assessed: (i) National Kidney Foundation (NKF) Kidney Disease Outcome Quality Initiative criteria: AVF outflow vein lumen diameter ≥6 mm and blood flow ≥600 mL/min; and (ii) University of Alabama at Birmingham (UAB) criteria: AVF outflow vein lumen diameter ≥4 mm and blood flow ≥500 mL/min. Performance characteristics were calculated for both criteria. Results: Compared to the NKF criteria, the UAB criteria had a higher sensitivity (89 vs.68%), but a lower specificity (42 vs. 70%) for unassisted AVF use. For radiocephalic AVFs, the UAB criteria had higher sensitivity (86 vs. 46%) and lower specificity (58 vs. 83%). For brachiocephalic AVFs, both UAB and NKF had high sensitivity (90 and 80%) but low specificity (21 and 53%), respectively. Conclusions: Using the UAB ultrasound criteria would minimize unnecessary early interventions in AVFs likely to mature without an intervention, but would delay interventions in AVFs that are unlikely to mature. The UAB criteria may be preferred in patients receiving a radiocephalic AVF. … (more)
- Is Part Of:
- Journal of vascular access. Volume 19:Issue 2(2018)
- Journal:
- Journal of vascular access
- Issue:
- Volume 19:Issue 2(2018)
- Issue Display:
- Volume 19, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 2
- Issue Sort Value:
- 2018-0019-0002-0000
- Page Start:
- 167
- Page End:
- 171
- Publication Date:
- 2018-03
- Subjects:
- Arteriovenous fistula -- Hemodialysis -- Ultrasound
Arterial catheterization -- Periodicals
Intravenous catheterization -- Periodicals
612.13 - Journal URLs:
- http://journals.sagepub.com/home/jva ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.5301/jva.5000818 ↗
- Languages:
- English
- ISSNs:
- 1129-7298
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8127.xml