Quantifying thumb opposition kinematics using dynamic computed tomography. Issue 9 (14th June 2016)
- Record Type:
- Journal Article
- Title:
- Quantifying thumb opposition kinematics using dynamic computed tomography. Issue 9 (14th June 2016)
- Main Title:
- Quantifying thumb opposition kinematics using dynamic computed tomography
- Authors:
- Kerkhof, F.D.
Brugman, E.
D'Agostino, P.
Dourthe, B.
van Lenthe, G.H.
Stockmans, F.
Jonkers, I.
Vereecke, E.E. - Abstract:
- Abstract: Current motion capture techniques all have shortcomings when applied to the 3D quantitative evaluation of thumb base motion. Dynamic CT might overcome these shortcomings but, so far, robustness of this technique in more than one specimen has not yet been demonstrated. The aim of the current study is to further evaluate the use of dynamic CT for quantification of thumb motion in a larger cadaveric study using a protocol which is feasible in a clinical context. A dynamic CT scan was acquired from six cadaveric human forearms, while a motion simulator imposed thumb opposition. After image acquisition and segmentation, carpal bone motion was quantified using helical axes. To enable comparisons between specimens, intersection points of the instantaneous helical axis with an anatomically defined plane were determined. Precision of the dynamic CT method, measured as variation in distances between silicon nitride beads between frames of a dynamic scan, was 0.43 mm (+/−0.09 mm) when fixed to the skin and 0.13 mm (+/−0.04 mm) when embedded into the bone. Absolute deviation between known and measured distances were not larger than 0.34 mm. We could demonstrate and quantify that thumb opposition is associated with motion at the trapeziometacarpal and scaphotrapezotrapezoidal joints. High consistency in motion patterns between specimen were found, while the radiation dose was limited. We conclude that dynamic CT can be used to visualize and quantify 3D thumb kinematics, makingAbstract: Current motion capture techniques all have shortcomings when applied to the 3D quantitative evaluation of thumb base motion. Dynamic CT might overcome these shortcomings but, so far, robustness of this technique in more than one specimen has not yet been demonstrated. The aim of the current study is to further evaluate the use of dynamic CT for quantification of thumb motion in a larger cadaveric study using a protocol which is feasible in a clinical context. A dynamic CT scan was acquired from six cadaveric human forearms, while a motion simulator imposed thumb opposition. After image acquisition and segmentation, carpal bone motion was quantified using helical axes. To enable comparisons between specimens, intersection points of the instantaneous helical axis with an anatomically defined plane were determined. Precision of the dynamic CT method, measured as variation in distances between silicon nitride beads between frames of a dynamic scan, was 0.43 mm (+/−0.09 mm) when fixed to the skin and 0.13 mm (+/−0.04 mm) when embedded into the bone. Absolute deviation between known and measured distances were not larger than 0.34 mm. We could demonstrate and quantify that thumb opposition is associated with motion at the trapeziometacarpal and scaphotrapezotrapezoidal joints. High consistency in motion patterns between specimen were found, while the radiation dose was limited. We conclude that dynamic CT can be used to visualize and quantify 3D thumb kinematics, making it a promising method to explore kinematics in vivo . … (more)
- Is Part Of:
- Journal of biomechanics. Volume 49:Issue 9(2016)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 49:Issue 9(2016)
- Issue Display:
- Volume 49, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 49
- Issue:
- 9
- Issue Sort Value:
- 2016-0049-0009-0000
- Page Start:
- 1994
- Page End:
- 1999
- Publication Date:
- 2016-06-14
- Subjects:
- Trapeziometacarpal joint -- TMC -- 4D CT -- HAM -- STT -- Medical imaging
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2016.05.008 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8119.xml