Optimization of throughput in semipreparative chiral liquid chromatography using stacked injection. Issue 10 (27th July 2017)
- Record Type:
- Journal Article
- Title:
- Optimization of throughput in semipreparative chiral liquid chromatography using stacked injection. Issue 10 (27th July 2017)
- Main Title:
- Optimization of throughput in semipreparative chiral liquid chromatography using stacked injection
- Authors:
- Taheri, Mohammadreza
Fotovati, Mohsen
Hosseini, Seyed‐Kiumars
Ghassempour, Alireza - Abstract:
- Abstract: An interesting mode of chromatography for preparation of pure enantiomers from pure samples is the method of stacked injection as a pseudocontinuous procedure. Maximum throughput and minimal production costs can be achieved by the use of total chiral column length in this mode of chromatography. To maximize sample loading, often touching bands of the two enantiomers is automatically achieved. Conventional equations show direct correlation between touching‐band loadability and the selectivity factor of two enantiomers. The important question for one who wants to obtain the highest throughput is "How to optimize different factors including selectivity, resolution, run time, and loading of the sample in order to save time without missing the touching‐band resolution?" To answer this question, tramadol and propranolol were separated on cellulose 3, 5‐dimethyl phenyl carbamate, as two pure racemic mixtures with low and high solubilities in mobile phase, respectively. The mobile phase composition consisted of n‐hexane solvent with alcohol modifier and diethylamine as the additive. A response surface methodology based on central composite design was used to optimize separation factors against the main responses. According to the stacked injection properties, two processes were investigated for maximizing throughput: one with a poorly soluble and another with a highly soluble racemic mixture. For each case, different optimization possibilities were inspected. It wasAbstract: An interesting mode of chromatography for preparation of pure enantiomers from pure samples is the method of stacked injection as a pseudocontinuous procedure. Maximum throughput and minimal production costs can be achieved by the use of total chiral column length in this mode of chromatography. To maximize sample loading, often touching bands of the two enantiomers is automatically achieved. Conventional equations show direct correlation between touching‐band loadability and the selectivity factor of two enantiomers. The important question for one who wants to obtain the highest throughput is "How to optimize different factors including selectivity, resolution, run time, and loading of the sample in order to save time without missing the touching‐band resolution?" To answer this question, tramadol and propranolol were separated on cellulose 3, 5‐dimethyl phenyl carbamate, as two pure racemic mixtures with low and high solubilities in mobile phase, respectively. The mobile phase composition consisted of n‐hexane solvent with alcohol modifier and diethylamine as the additive. A response surface methodology based on central composite design was used to optimize separation factors against the main responses. According to the stacked injection properties, two processes were investigated for maximizing throughput: one with a poorly soluble and another with a highly soluble racemic mixture. For each case, different optimization possibilities were inspected. It was revealed that resolution is a crucial response for separations of this kind. Peak area and run time are two critical parameters in optimization of stacked injection for binary mixtures which have low solubility in the mobile phase. Abstract : A method development based on stacked injection to overcome overloading problem of poorly soluble enentiomers. … (more)
- Is Part Of:
- Chirality. Volume 29:Issue 10(2017)
- Journal:
- Chirality
- Issue:
- Volume 29:Issue 10(2017)
- Issue Display:
- Volume 29, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 29
- Issue:
- 10
- Issue Sort Value:
- 2017-0029-0010-0000
- Page Start:
- 579
- Page End:
- 588
- Publication Date:
- 2017-07-27
- Subjects:
- enantiopurification -- method development -- preparative chiral chromatography -- propranolol -- sample loading -- stacked injection -- throughput -- tramadol
Chirality -- Periodicals
Pharmaceutical chemistry -- Periodicals
541.22 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1520-636X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/chir.22727 ↗
- Languages:
- English
- ISSNs:
- 0899-0042
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3181.124450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8126.xml