Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials. Issue 6 (15th June 2015)
- Record Type:
- Journal Article
- Title:
- Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials. Issue 6 (15th June 2015)
- Main Title:
- Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials
- Authors:
- Cross, Troy J.
Lalande, Sophie
Hyatt, Robert E.
Johnson, Bruce D. - Abstract:
- Abstract: The measurement of esophageal pressure allows for the calculation of several important and clinically useful parameters of respiratory mechanics. Esophageal pressure is often measured with balloon‐tipped catheters. These catheters may be handmade from natural latex condoms and polyethylene tubing. Given the potential of natural latex to cause allergic reaction, it is important to determine whether esophageal catheter balloons can be fabricated, by hand, using nonlatex condoms as construction materials. To determine the static and dynamic response characteristics of esophageal balloon catheters handmade from latex and nonlatex materials, six esophageal catheter balloons were constructed from each of the following condom materials: natural latex, synthetic polyisoprene, and polyurethane (18 total). Static compliance and working volume range of each balloon catheter was obtained from their pressure‐volume characteristics in water. The dynamic response of balloon catheters were measured via a pressure "step" test, from which a third‐order underdamped transfer function was modeled. The dynamic ranges of balloon catheters were characterized by the frequencies corresponding to ±5% amplitude‐ and phase‐distortion ( f A5% and f φ 5% ). Balloon catheters handmade from polyurethane condoms displayed the smallest working volume range and lowest static balloon compliance. Despite this lower compliance, f A 5% and f φ 5% were remarkably similar between all balloon materials. OurAbstract: The measurement of esophageal pressure allows for the calculation of several important and clinically useful parameters of respiratory mechanics. Esophageal pressure is often measured with balloon‐tipped catheters. These catheters may be handmade from natural latex condoms and polyethylene tubing. Given the potential of natural latex to cause allergic reaction, it is important to determine whether esophageal catheter balloons can be fabricated, by hand, using nonlatex condoms as construction materials. To determine the static and dynamic response characteristics of esophageal balloon catheters handmade from latex and nonlatex materials, six esophageal catheter balloons were constructed from each of the following condom materials: natural latex, synthetic polyisoprene, and polyurethane (18 total). Static compliance and working volume range of each balloon catheter was obtained from their pressure‐volume characteristics in water. The dynamic response of balloon catheters were measured via a pressure "step" test, from which a third‐order underdamped transfer function was modeled. The dynamic ranges of balloon catheters were characterized by the frequencies corresponding to ±5% amplitude‐ and phase‐distortion ( f A5% and f φ 5% ). Balloon catheters handmade from polyurethane condoms displayed the smallest working volume range and lowest static balloon compliance. Despite this lower compliance, f A 5% and f φ 5% were remarkably similar between all balloon materials. Our findings suggest that polyisoprene condoms are an ideal nonlatex construction material to use when fabricating esophageal catheter balloons by hand. Abstract : Esophageal pressure is often measured with balloon‐tipped catheters. These catheters may be handmade from natural latex condoms and polyethylene tubing. Given the potential of natural latex to cause allergic reaction, we determined whether esophageal catheter balloons can be fabricated, by hand, using nonlatex condoms as construction materials. In this paper, we show that polyisoprene condoms are an ideal nonlatex construction material to use when fabricating esophageal catheter balloons by hand. … (more)
- Is Part Of:
- Physiological reports. Volume 3:Issue 6(2015:Jun.)
- Journal:
- Physiological reports
- Issue:
- Volume 3:Issue 6(2015:Jun.)
- Issue Display:
- Volume 3, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 3
- Issue:
- 6
- Issue Sort Value:
- 2015-0003-0006-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2015-06-15
- Subjects:
- Balloon catheter -- esophageal pressure -- latex -- nonlatex
Physiology -- Periodicals
571 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2051-817X ↗
http://physreports.physiology.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.14814/phy2.12426 ↗
- Languages:
- English
- ISSNs:
- 2051-817X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8106.xml