Methodological improvements in voxel‐based analysis of diffusion tensor images: Applications to study the impact of apolipoprotein E on white matter integrity. Issue 2 (15th April 2013)
- Record Type:
- Journal Article
- Title:
- Methodological improvements in voxel‐based analysis of diffusion tensor images: Applications to study the impact of apolipoprotein E on white matter integrity. Issue 2 (15th April 2013)
- Main Title:
- Methodological improvements in voxel‐based analysis of diffusion tensor images: Applications to study the impact of apolipoprotein E on white matter integrity
- Authors:
- Newlander, Shawn M.
Chu, Alan
Sinha, Usha S.
Lu, Po H.
Bartzokis, George - Abstract:
- Abstract : Purpose: To identify regional differences in apparent diffusion coefficient (ADC) and fractional anisotropy (FA) using customized preprocessing before voxel‐based analysis (VBA) in 14 normal subjects with the specific genes that decrease (apolipoprotein [APO] E ε2) and that increase (APOE ε4) the risk of Alzheimer's disease. Materials and Methods: Diffusion tensor images (DTI) acquired at 1.5 Tesla were denoised with a total variation tensor regularization algorithm before affine and nonlinear registration to generate a common reference frame for the image volumes of all subjects. Anisotropic and isotropic smoothing with varying kernel sizes was applied to the aligned data before VBA to determine regional differences between cohorts segregated by allele status. Results: VBA on the denoised tensor data identified regions of reduced FA in APOE ε4 compared with the APOE ε2 healthy older carriers. The most consistent results were obtained using the denoised tensor and anisotropic smoothing before statistical testing. In contrast, isotropic smoothing identified regional differences for small filter sizes alone, emphasizing that this method introduces bias in FA values for higher kernel sizes. Conclusion: Voxel‐based DTI analysis can be performed on low signal to noise ratio images to detect subtle regional differences in cohorts using the proposed preprocessing techniques.J. Magn. Reson. Imaging 2014;39:387–397 . ©2013 Wiley Periodicals, Inc .
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 39:Issue 2(2014)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 39:Issue 2(2014)
- Issue Display:
- Volume 39, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 39
- Issue:
- 2
- Issue Sort Value:
- 2014-0039-0002-0000
- Page Start:
- 387
- Page End:
- 397
- Publication Date:
- 2013-04-15
- Subjects:
- diffusion tensor imaging -- voxel‐based analysis -- tensor denoising -- anisotropic smoothing -- APOE
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24157 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8099.xml