Concurrent Validity of Daily Activity Data From Medtronic ICD/CRT Devices and the Actigraph GT3X Triaxial Accelerometer: A Pilot Study. Issue 1 (January 2017)
- Record Type:
- Journal Article
- Title:
- Concurrent Validity of Daily Activity Data From Medtronic ICD/CRT Devices and the Actigraph GT3X Triaxial Accelerometer: A Pilot Study. Issue 1 (January 2017)
- Main Title:
- Concurrent Validity of Daily Activity Data From Medtronic ICD/CRT Devices and the Actigraph GT3X Triaxial Accelerometer
- Authors:
- Shoemaker, Michael J.
Cartwright, Kelly
Hanson, Kim
Serba, Deb
Dickinson, Michael G.
Kowalk, Amy - Abstract:
- Abstract : Purpose: The purpose of this pilot study was to examine the concurrent validity of daily activity data from Medtronic implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices and the Actigraph GT3X triaxial accelerometer in patients with heart failure (HF). Methods: Analysis of the first 16 subjects with HF completing 3-month follow-up in a randomized trial with a secondary purpose to examine concurrent validity of Medtronic ICD/CRT device-based daily activity and the following Actigraph GT3X parameters: hours of activity per day, activity counts, and steps per day. Daily activity data were measured at baseline and 3-month follow-up and analyzed using Pearson correlation coefficients to measure intraindividual correlations and Bland–Altman plots to examine agreement between devices. Results: Moderate-to-strong, statistically significant correlations were found between the Medtronic ICD/CRT and Actigraph GT3X devices for all parameters measured. The Bland–Altman plots revealed approximately 0.80 hours less activity per day measured by the Medtronic ICD/CRT compared with the Actigraph GT3X. Strong agreement for the 7-day average and moderate-to-strong agreement for all daily observations for hours of activity per day was found between both devices. Similarly, there was moderate-to-strong agreement for change in hours of activity and steps per day between baseline and 3-month follow-up. Conclusions: The Medtronic ICD/CRTAbstract : Purpose: The purpose of this pilot study was to examine the concurrent validity of daily activity data from Medtronic implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices and the Actigraph GT3X triaxial accelerometer in patients with heart failure (HF). Methods: Analysis of the first 16 subjects with HF completing 3-month follow-up in a randomized trial with a secondary purpose to examine concurrent validity of Medtronic ICD/CRT device-based daily activity and the following Actigraph GT3X parameters: hours of activity per day, activity counts, and steps per day. Daily activity data were measured at baseline and 3-month follow-up and analyzed using Pearson correlation coefficients to measure intraindividual correlations and Bland–Altman plots to examine agreement between devices. Results: Moderate-to-strong, statistically significant correlations were found between the Medtronic ICD/CRT and Actigraph GT3X devices for all parameters measured. The Bland–Altman plots revealed approximately 0.80 hours less activity per day measured by the Medtronic ICD/CRT compared with the Actigraph GT3X. Strong agreement for the 7-day average and moderate-to-strong agreement for all daily observations for hours of activity per day was found between both devices. Similarly, there was moderate-to-strong agreement for change in hours of activity and steps per day between baseline and 3-month follow-up. Conclusions: The Medtronic ICD/CRT devices seem to be a sufficiently accurate, responsive measure of daily activity in patients with HF when compared with the Actigraph GT3X. … (more)
- Is Part Of:
- Cardiopulmonary physical therapy journal. Volume 28:Issue 1(2017)
- Journal:
- Cardiopulmonary physical therapy journal
- Issue:
- Volume 28:Issue 1(2017)
- Issue Display:
- Volume 28, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 28
- Issue:
- 1
- Issue Sort Value:
- 2017-0028-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-01
- Subjects:
- daily activity -- heart failure -- physical activity
Cardiopulmonary system -- Diseases -- Physical therapy -- Periodicals
Cardiovascular system -- Diseases -- Physical therapy -- Periodicals
Lungs -- Diseases -- Physical therapy -- Periodicals
Periodicals
616.1062 - Journal URLs:
- http://journals.lww.com/cptj/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://cptjournal.org ↗
http://gateway.proquest.com/openurl?url_ver=Z39.88-2004&res_dat=xri:pqd&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft_dat=xri:pqd:PMID=39115 ↗ - DOI:
- 10.1097/CPT.0000000000000042 ↗
- Languages:
- English
- ISSNs:
- 1541-7891
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3051.437050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8088.xml