Accuracy of equilibrium magnetization mapping in sliced two‐dimensional spoiled gradient‐recalled echo pulse sequence with variable flip angle. Issue 5 (6th February 2013)
- Record Type:
- Journal Article
- Title:
- Accuracy of equilibrium magnetization mapping in sliced two‐dimensional spoiled gradient‐recalled echo pulse sequence with variable flip angle. Issue 5 (6th February 2013)
- Main Title:
- Accuracy of equilibrium magnetization mapping in sliced two‐dimensional spoiled gradient‐recalled echo pulse sequence with variable flip angle
- Authors:
- Kuribayashi, Hideto
Sekino, Masaki
Minowa, Takuya
Maitani, Yoshie
Ohsaki, Hiroyuki
Tsushima, Shohji
Hirai, Shuichiro
Ueda, Masayuki
Katayama, Yasuo - Abstract:
- Abstract : Purpose: To evaluate the accuracy of an equilibrium magnetization (M0 ) map obtained using a two‐dimensional (2D) spoiled gradient‐recalled echo (SPGR) pulse sequence with variable flip angle (VFA). Materials and Methods: Single‐slice 2D SPGR images of 4% agar gel phantoms with different gadolinium‐diethylene triamine pentaacetic acid (Gd‐DTPA) concentrations (0–1 mM) were obtained with a VFA (2–30°). The 2D SPGR‐VFA data were acquired with different repetition times (TRs; 7.8–117.2 ms), Gaussian and sinc RF pulses, and different field strengths (4.7, 7, and 9.4 Tesla). M0 and T1 maps were calculated from the 2D SPGR‐VFA data. M0 and T1 values were compared with those calculated from free‐relaxed 2D gradient‐recalled echo (GRE) images and inversion recovery‐prepared 2D SPGR images. The M0 and T1 slice profiles were also investigated. Results: Consistent M0 values were obtained, regardless of the different Gd concentrations, TRs, and pulse sequences. The M0 slice profiles calculated from the sliced SPGR‐VFA data quantitatively reproduced those calculated from the free‐relaxed sliced GRE. In contrast, the T1 values calculated from the 2D SPGR‐VFA data were underestimated at a high Gd concentration, short TR, and Gaussian RF pulse. Conclusion: M0 values calculated from 2D SPGR‐VFA images are highly quantitative. J. Magn. Reson. Imaging 2013;38:1245–1250. © 2013 Wiley Periodicals, Inc.
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 38:Issue 5(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 38:Issue 5(2013)
- Issue Display:
- Volume 38, Issue 5 (2013)
- Year:
- 2013
- Volume:
- 38
- Issue:
- 5
- Issue Sort Value:
- 2013-0038-0005-0000
- Page Start:
- 1245
- Page End:
- 1250
- Publication Date:
- 2013-02-06
- Subjects:
- equilibrium magnetization map -- M0 map -- quantitative imaging -- slice profile -- T1 map -- 2D SPGR‐VFA
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24023 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8084.xml