Subtraction artifacts and frequency (Mis‐)alignment in J‐difference GABA editing. Issue 4 (27th November 2012)
- Record Type:
- Journal Article
- Title:
- Subtraction artifacts and frequency (Mis‐)alignment in J‐difference GABA editing. Issue 4 (27th November 2012)
- Main Title:
- Subtraction artifacts and frequency (Mis‐)alignment in J‐difference GABA editing
- Authors:
- Evans, C. John
Puts, Nicolaas A.J.
Robson, Siân E.
Boy, Frederic
McGonigle, David J.
Sumner, Petroc
Singh, Krish D.
Edden, Richard A.E. - Abstract:
- Abstract : Purpose: To compare the repeatability of γ‐aminobutyric acid (GABA) measurements using J ‐difference editing, before and after spectral realignment—a technique which has previously been demonstrated to improve the quality of J ‐difference GABA spectra. Materials and Methods: We performed in vivo measurements in three brain regions (occipital, sensorimotor, and dorsolateral prefrontal cortex [DLPFC]), and analyzed these using alternative alignment approaches to evaluate the impact of alignment on repeatability: "Independent alignment" (aligning each subspectrum independently) and "Pairwise alignment" (aligning each on and off subspectrum as a pair) were compared. Results: Pairwise alignment improved the group mean coefficient of variation in all regions; 0.4% in occipital, 1.1% in sensorimotor, and 1.1% in DLPFC. Independent alignment resulted in subtraction artifacts in the majority of cases, and increased the coefficient of variation in the DLPFC by 9.4%. Simulations demonstrate that the GABA quantification error in datasets with high B 0 drift, is 4.5% without alignment, but <1% with optimal alignment. Conclusion: Pairwise alignment improves the repeatability of GABA spectroscopy data. However, independently aligning all on and off subspectra can lead to artifacts and worse repeatability when compared with nonaligned data. J. Magn. Reson. Imaging 2013;38:970–975. © 2012 Wiley Periodicals, Inc.
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 38:Issue 4(2013)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 38:Issue 4(2013)
- Issue Display:
- Volume 38, Issue 4 (2013)
- Year:
- 2013
- Volume:
- 38
- Issue:
- 4
- Issue Sort Value:
- 2013-0038-0004-0000
- Page Start:
- 970
- Page End:
- 975
- Publication Date:
- 2012-11-27
- Subjects:
- MRS -- GABA -- frequency alignment -- subtraction artifact -- repeatability
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.23923 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8102.xml