Cochlear Implantation in Cases of Unilateral Hearing Loss: Initial Localization Abilities. Issue 5 (September 2017)
- Record Type:
- Journal Article
- Title:
- Cochlear Implantation in Cases of Unilateral Hearing Loss: Initial Localization Abilities. Issue 5 (September 2017)
- Main Title:
- Cochlear Implantation in Cases of Unilateral Hearing Loss
- Authors:
- Dillon, Margaret T.
Buss, Emily
Anderson, Meredith L.
King, English R.
Deres, Ellen J.
Buchman, Craig A.
Brown, Kevin D.
Pillsbury, Harold C. - Abstract:
- Abstract : Objectives: The present study evaluated early auditory localization abilities of cochlear implant (CI) recipients with normal or near-normal hearing (NH) in the contralateral ear. The goal of the study was to better understand the effect of CI listening experience on localization in this population. Design: Twenty participants with unilateral hearing loss enrolled in a prospective clinical trial assessing outcomes of cochlear implantation (ClinicalTrials.gov Identifier: NCT02203305). All participants received the MED-EL Standard electrode array, were fit with an ear-level audio processor, and listened with the FS4 coding strategy. Localization was assessed in the sound field using an 11-speaker array with speakers uniformly positioned on a horizontal, semicircular frame. Stimuli were 200-msec speech-shaped noise bursts. The intensity level (52, 62, and 72 dB SPL) and sound source were randomly interleaved across trials. Participants were tested preoperatively, and 1, 3, and 6 months after activation of the audio processor. Performance was evaluated in two conditions at each interval: (1) unaided (NH ear alone [NH-alone] condition), and (2) aided, with either a bone conduction hearing aid (preoperative interval; bone conduction hearing aid + NH condition) or a CI (postoperative intervals; CI + NH condition). Performance was evaluated by comparing root-mean-squared (RMS) error between listening conditions and between measurement intervals. Results: Mean RMS errorAbstract : Objectives: The present study evaluated early auditory localization abilities of cochlear implant (CI) recipients with normal or near-normal hearing (NH) in the contralateral ear. The goal of the study was to better understand the effect of CI listening experience on localization in this population. Design: Twenty participants with unilateral hearing loss enrolled in a prospective clinical trial assessing outcomes of cochlear implantation (ClinicalTrials.gov Identifier: NCT02203305). All participants received the MED-EL Standard electrode array, were fit with an ear-level audio processor, and listened with the FS4 coding strategy. Localization was assessed in the sound field using an 11-speaker array with speakers uniformly positioned on a horizontal, semicircular frame. Stimuli were 200-msec speech-shaped noise bursts. The intensity level (52, 62, and 72 dB SPL) and sound source were randomly interleaved across trials. Participants were tested preoperatively, and 1, 3, and 6 months after activation of the audio processor. Performance was evaluated in two conditions at each interval: (1) unaided (NH ear alone [NH-alone] condition), and (2) aided, with either a bone conduction hearing aid (preoperative interval; bone conduction hearing aid + NH condition) or a CI (postoperative intervals; CI + NH condition). Performance was evaluated by comparing root-mean-squared (RMS) error between listening conditions and between measurement intervals. Results: Mean RMS error for the soft, medium, and loud levels were 66°, 64°, and 69° in the NH-alone condition and 72°, 66°, and 70° in the bone conduction hearing aid + NH condition. Participants experienced a significant improvement in localization in the CI + NH condition at the 1-month interval (38°, 35°, and 38°) as compared with the preoperative NH-alone condition. Localization in the CI + NH condition continued to improve through the 6-month interval. Mean RMS errors were 28°, 25°, and 28° in the CI + NH condition at the 6-month interval. Conclusions: Adult CI recipients with normal or near-normal hearing in the contralateral ear experienced significant improvement in localization after 1 month of device use, and continued to improve through the 6-month interval. The present results show that binaural acclimatization in CI users with unilateral hearing loss can progress rapidly, with marked improvements in performance observed after only 1 month of listening experience. … (more)
- Is Part Of:
- Ear and hearing. Volume 38:Issue 5(2017)
- Journal:
- Ear and hearing
- Issue:
- Volume 38:Issue 5(2017)
- Issue Display:
- Volume 38, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 38
- Issue:
- 5
- Issue Sort Value:
- 2017-0038-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-09
- Subjects:
- Cochlear implant -- Localization -- Single-sided deafness -- Unilateral hearing loss
Hearing disorders -- Periodicals
Audiology -- Periodicals
612.85 - Journal URLs:
- http://journals.lww.com/ear-hearing/toc/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1097/AUD.0000000000000430 ↗
- Languages:
- English
- ISSNs:
- 0196-0202
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3642.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8061.xml