Multiparametric Magnetic Resonance Imaging of the Prostate: Repeatability of Volume and Apparent Diffusion Coefficient Quantification. Issue 9 (September 2017)
- Record Type:
- Journal Article
- Title:
- Multiparametric Magnetic Resonance Imaging of the Prostate: Repeatability of Volume and Apparent Diffusion Coefficient Quantification. Issue 9 (September 2017)
- Main Title:
- Multiparametric Magnetic Resonance Imaging of the Prostate
- Authors:
- Fedorov, Andriy
Vangel, Mark G.
Tempany, Clare M.
Fennessy, Fiona M. - Abstract:
- Abstract : Objectives: The aim of this study was to evaluate the repeatability of a region of interest (ROI) volume and mean apparent diffusion coefficient (ADC) in standard-of-care 3 T multiparametric magnetic resonance imaging (mpMRI) of the prostate obtained with the use of endorectal coil. Materials and Methods: This prospective study was Health Insurance Portability and Accountability Act compliant, with institutional review board approval and written informed consent. Men with confirmed or suspected treatment-naive prostate cancer scheduled for mpMRI were offered a repeat mpMRI within 2 weeks. Regions of interest corresponding to the whole prostate gland, the entire peripheral zone (PZ), normal PZ, and suspected tumor ROI (tROI) on axial T2-weighted, dynamic contrast-enhanced subtract, and ADC images were annotated and assessed using Prostate Imaging Reporting and Data System (PI-RADS) v2. Repeatability of the ROI volume for each of the analyzed image types and mean ROI ADC was summarized with repeatability coefficient (RC) and RC%. Results: A total of 189 subjects were approached to participate in the study. Of 40 patients that gave initial agreement, 15 men underwent 2 mpMRI examinations and completed the study. Peripheral zone tROIs were identified in 11 subjects. Tumor ROI volume was less than 0.5 mL in 8 of 11 subjects. PI-RADS categories were identical between baseline-repeat studies in 11/15 subjects and differed by 1 point in 4/15. Peripheral zone tROI volumeAbstract : Objectives: The aim of this study was to evaluate the repeatability of a region of interest (ROI) volume and mean apparent diffusion coefficient (ADC) in standard-of-care 3 T multiparametric magnetic resonance imaging (mpMRI) of the prostate obtained with the use of endorectal coil. Materials and Methods: This prospective study was Health Insurance Portability and Accountability Act compliant, with institutional review board approval and written informed consent. Men with confirmed or suspected treatment-naive prostate cancer scheduled for mpMRI were offered a repeat mpMRI within 2 weeks. Regions of interest corresponding to the whole prostate gland, the entire peripheral zone (PZ), normal PZ, and suspected tumor ROI (tROI) on axial T2-weighted, dynamic contrast-enhanced subtract, and ADC images were annotated and assessed using Prostate Imaging Reporting and Data System (PI-RADS) v2. Repeatability of the ROI volume for each of the analyzed image types and mean ROI ADC was summarized with repeatability coefficient (RC) and RC%. Results: A total of 189 subjects were approached to participate in the study. Of 40 patients that gave initial agreement, 15 men underwent 2 mpMRI examinations and completed the study. Peripheral zone tROIs were identified in 11 subjects. Tumor ROI volume was less than 0.5 mL in 8 of 11 subjects. PI-RADS categories were identical between baseline-repeat studies in 11/15 subjects and differed by 1 point in 4/15. Peripheral zone tROI volume RC (RC%) was 233 mm 3 (71%) on axial T2-weighted, 422 mm 3 (112%) on ADC, and 488 mm 3 (119%) on dynamic contrast-enhanced subtract. Apparent diffusion coefficient ROI mean RC (RC%) were 447 × 10 −6 mm −2 /s (42%) in PZ tROI and 471 × 10 −6 mm −2 /s (30%) in normal PZ. Significant difference in repeatability of the tROI volume across series was observed ( P < 0.005). The mean ADC RC% was lower than volume RC% for tROI ADC ( P < 0.05). Conclusions: PI-RADS v2 overall assessment was highly repeatable. Multiparametric magnetic resonance imaging sequences differ in volume measurement repeatability. The mean tROI ADC is more repeatable compared with tROI volume in ADC. Repeatability of prostate ADC is comparable with that in other abdominal organs. Abstract : Supplemental digital content is available in the text. … (more)
- Is Part Of:
- Investigative radiology. Volume 52:Issue 9(2017:Sep.)
- Journal:
- Investigative radiology
- Issue:
- Volume 52:Issue 9(2017:Sep.)
- Issue Display:
- Volume 52, Issue 9 (2017)
- Year:
- 2017
- Volume:
- 52
- Issue:
- 9
- Issue Sort Value:
- 2017-0052-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-09
- Subjects:
- magnetic resonance imaging -- prostate -- apparent diffusion coefficient -- dynamic contrast-enhanced imaging -- repeatability -- quantitative imaging
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000382 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8064.xml