Emergency Percutaneous, Bicaval Double-Lumen, ECMO Cannulation in Neonates and Infants: Insights from Three Consecutive Cases. Issue 9 (September 2015)
- Record Type:
- Journal Article
- Title:
- Emergency Percutaneous, Bicaval Double-Lumen, ECMO Cannulation in Neonates and Infants: Insights from Three Consecutive Cases. Issue 9 (September 2015)
- Main Title:
- Emergency Percutaneous, Bicaval Double-Lumen, ECMO Cannulation in Neonates and Infants: Insights from Three Consecutive Cases
- Authors:
- Moscatelli, Andrea
Buratti, Silvia
Gregoretti, Cesare
Lampugnani, Elisabetta
Salvati, Pietro
Marasini, Maurizio
Ribera, Elena
Fulcheri, Ezio
Tuo, Pietro - Abstract:
- Background: Veno-venous extracorporeal membrane oxygenation (ECMO) is probably the preferable configuration to assist children with respiratory failure who do not respond to maximized conventional therapies. The single-vessel, double-lumen approach through the internal jugular vein is extremely advantageous, especially in infants, where femoral access presents limitations related to the small dimensions of the veins. In case of emergencies, ECMO might need to be started at the bedside, without the availability of fluoroscopic guidance. To our knowledge, a completely percutaneous approach has not been reported before in children younger than 1 year and weighing less than 5 kg. Methods: We describe 3 cases of emergency bedside, percutaneous, bicaval double-lumen cannulation under real-time transthoracic ultrasound control in 2 neonates and 1 infant. Results: In our experience, this approach proved to be safe, effective and time saving, while minimizing bleeding from the cannula insertion site. Cannulation times, from decision making to the beginning of ECMO flow, were 30, 28, 25 minutes respectively, from patient 1 to 3. We do not report any cannula-related injury to vessels and heart structures. Conclusions: Our preliminary data suggest that, with the described precautions, percutaneous, echo-guided, bicaval double-lumen cannulation in neonates and infants could be effective and free from major complications. Further evaluation should be warranted in the neonatal population.
- Is Part Of:
- International journal of artificial organs. Volume 38:Issue 9(2015:Sep.)
- Journal:
- International journal of artificial organs
- Issue:
- Volume 38:Issue 9(2015:Sep.)
- Issue Display:
- Volume 38, Issue 9 (2015)
- Year:
- 2015
- Volume:
- 38
- Issue:
- 9
- Issue Sort Value:
- 2015-0038-0009-0000
- Page Start:
- 517
- Page End:
- 521
- Publication Date:
- 2015-09
- Subjects:
- ECMO -- Percutaneous -- Bicaval double-lumen cannulation -- Echo-guided -- Newborn -- Infant
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/3676874.html ↗
http://www.artificial-organs.com/ ↗
http://www.wichtig-publisher.com/jao/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/loi/jaoa ↗
https://us.sagepub.com/en-us/nam/the-international-journal-of-artificial-organs/journal203459 ↗ - DOI:
- 10.5301/ijao.5000432 ↗
- Languages:
- English
- ISSNs:
- 0391-3988
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8038.xml