Sadikoglu, Telem G - Abstract:
- In this study, single layer vascular grafts were produced by a custom designed electrospinning apparatus. Both polymer type and rotational speed of the rotating collector were varied in single layer designs. Surface morphology of the fibrous scaffolds was observed under scanning electron microscope. Fiber diameter was measured and fiber orientation was analyzed by Image J Software. Scanning electron microscope images and fiber orientation analysis results indicated that fiber orientation was improved with increased rotational speed. Ultimate tensile strength and elongation at break values of the scaffolds were tested in planar forms. In addition to the experimental analysis, statistical analysis was also realized; 2 2 full factorial design was adapted to the test results in order to investigate the effect of polymer type and the rotational speed on elongation at break and ultimate tensile strength values. Results have shown that both polymer type and the rotational speed of the collector significantly influenced ultimate tensile strength and elongation at break values of scaffolds tested in the radial direction. When the scaffolds tested in the horizontal direction were considered, while both factors have had a poor effect on ultimate tensile strength, they were either significant or were very close to the confidence limits. On the other hand, the interaction effect of factors had a statistically significant influence on mechanical properties of both testing directions. TheIn this study, single layer vascular grafts were produced by a custom designed electrospinning apparatus. Both polymer type and rotational speed of the rotating collector were varied in single layer designs. Surface morphology of the fibrous scaffolds was observed under scanning electron microscope. Fiber diameter was measured and fiber orientation was analyzed by Image J Software. Scanning electron microscope images and fiber orientation analysis results indicated that fiber orientation was improved with increased rotational speed. Ultimate tensile strength and elongation at break values of the scaffolds were tested in planar forms. In addition to the experimental analysis, statistical analysis was also realized; 2 2 full factorial design was adapted to the test results in order to investigate the effect of polymer type and the rotational speed on elongation at break and ultimate tensile strength values. Results have shown that both polymer type and the rotational speed of the collector significantly influenced ultimate tensile strength and elongation at break values of scaffolds tested in the radial direction. When the scaffolds tested in the horizontal direction were considered, while both factors have had a poor effect on ultimate tensile strength, they were either significant or were very close to the confidence limits. On the other hand, the interaction effect of factors had a statistically significant influence on mechanical properties of both testing directions. The achieved results supported by statistical analysis can provide a reference for further studies in designing multilayer vascular grafts. … (more)
- Is Part Of:
- Journal of industrial textiles. Volume 47:Number 6(2018)
- Journal:
- Journal of industrial textiles
- Issue:
- Volume 47:Number 6(2018)
- Issue Display:
- Volume 47, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 47
- Issue:
- 6
- Issue Sort Value:
- 2018-0047-0006-0000
- Page Start:
- 1378
- Page End:
- 1391
- Publication Date:
- 2018-02
- Subjects:
- Vascular grafts -- electrospinning -- polycaprolactone -- polylactide-co-caprolactone -- full factorial design
Textile fabrics -- Periodicals
Textile industry -- Periodicals
677.005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
- DOI:
- 10.1177/1528083717690614 ↗
- Languages:
- English
- ISSNs:
- 1528-0837
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8051.xml