Ventilation/perfusion single-photon emission computed tomography: a service evaluation. Issue 8 (August 2017)
- Record Type:
- Journal Article
- Title:
- Ventilation/perfusion single-photon emission computed tomography: a service evaluation. Issue 8 (August 2017)
- Main Title:
- Ventilation/perfusion single-photon emission computed tomography
- Authors:
- Parekh, Amit
Graham, Richard
Redman, Stewart - Abstract:
- Abstract : Objectives: To identify the positive rate and negative predictive value (NPV) of our ventilation/perfusion (V/Q) single-photon emission computed tomography (SPECT) service as respective markers of overcalling (false positives) and undercalling (false negatives). We also identified the indeterminate rate as an indicator of the technical quality of the scans and reporter confidence. Patients and methods: V/Q SPECT studies carried out over 5 years were classified into positive, negative and indeterminate results. Patients who had died or had pulmonary emboli on imaging within 3 months of a negative V/Q SPECT were identified as false negatives, from which the NPV was calculated. The total number of positive and indeterminate studies as a proportion of all studies was calculated as the positive and indeterminate rates. Results: The positive rate, NPV and indeterminate rates in nonpregnant patients were 24, 98.7–100 and 3.6%, respectively. The positive rate, NPV and indeterminate rates in pregnant patients were 6.8, 100 and 2.3%, respectively. Conclusion: The positive rate and NPV for nonpregnant patients were similar to the published literature. This suggests that we provide a safe service. The indeterminate rate was slightly higher than the stated guidelines. The study shows that the positive rate and NPV are achievable indicators of potential overcalling and undercalling in a V/Q SPECT service. This is also one of the first studies to report a positive rate inAbstract : Objectives: To identify the positive rate and negative predictive value (NPV) of our ventilation/perfusion (V/Q) single-photon emission computed tomography (SPECT) service as respective markers of overcalling (false positives) and undercalling (false negatives). We also identified the indeterminate rate as an indicator of the technical quality of the scans and reporter confidence. Patients and methods: V/Q SPECT studies carried out over 5 years were classified into positive, negative and indeterminate results. Patients who had died or had pulmonary emboli on imaging within 3 months of a negative V/Q SPECT were identified as false negatives, from which the NPV was calculated. The total number of positive and indeterminate studies as a proportion of all studies was calculated as the positive and indeterminate rates. Results: The positive rate, NPV and indeterminate rates in nonpregnant patients were 24, 98.7–100 and 3.6%, respectively. The positive rate, NPV and indeterminate rates in pregnant patients were 6.8, 100 and 2.3%, respectively. Conclusion: The positive rate and NPV for nonpregnant patients were similar to the published literature. This suggests that we provide a safe service. The indeterminate rate was slightly higher than the stated guidelines. The study shows that the positive rate and NPV are achievable indicators of potential overcalling and undercalling in a V/Q SPECT service. This is also one of the first studies to report a positive rate in pregnant patients undergoing V/Q SPECT that other institutions can use as a standard when evaluating their services. … (more)
- Is Part Of:
- Nuclear medicine communications. Volume 38:Issue 8(2017:Aug.)
- Journal:
- Nuclear medicine communications
- Issue:
- Volume 38:Issue 8(2017:Aug.)
- Issue Display:
- Volume 38, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 38
- Issue:
- 8
- Issue Sort Value:
- 2017-0038-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-08
- Subjects:
- pulmonary emboli -- service evaluation -- ventilation/perfusion single-photon emission computed tomography
Nuclear medicine -- Periodicals
616.07575 - Journal URLs:
- http://journals.lww.com/nuclearmedicinecomm/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://www.lww.com/Product/0143-3636 ↗ - DOI:
- 10.1097/MNM.0000000000000693 ↗
- Languages:
- English
- ISSNs:
- 0143-3636
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6180.923000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8049.xml