Optimizing Radiation Dose in Computed Tomography of Articular Fractures. Issue 8 (August 2017)
- Record Type:
- Journal Article
- Title:
- Optimizing Radiation Dose in Computed Tomography of Articular Fractures. Issue 8 (August 2017)
- Main Title:
- Optimizing Radiation Dose in Computed Tomography of Articular Fractures
- Authors:
- Mansfield, Colin
Ali, Sayed
Komperda, Kazimierz
Zhao, Huaqing
Rehman, Saqib - Abstract:
- Abstract : Objectives: To determine whether a substantially lowered radiation protocol would provide satisfactory information for the surgeon, using the distal tibia as a model. Methods: Eleven adult cadaveric distal tibia specimens were used to create Orthopaedic Trauma Association (OTA/AO) 43C distal tibia fractures with varying displacements in 2 planes. Each specimen was scanned at 3 modified protocols, which were then subsequently read by both qualified attending orthopaedists and midlevel residents. Observer reliability was evaluated, as well as confidence levels of identifying fracture pattern and treatment protocols. Results: On average, there was less than a millimeter of variability in the measured gap to true gap as a whole (mean = 0.74 mm, P < 0.0001). With regard to measurements in gap, pattern, and treatment plans, no significant difference was found between CT images acquired with standard (110 mAs) compared with medium (60 mAs; mean 0.0 mm, P = 1.0; k = 0.14, P = 0.56; k = 0.38, P = 0.13, respectively) and low protocols (45 mAs; mean 0.01 mm, P = 0.95; k = 0.24, P = 0.32; k = 0.31, P = 0.13, respectively). Furthermore, no significant difference was found in measuring step-off across standard, medium, and low radiation dose (0.21 mm, P = 0.46; 0.28 mm, P = 0.39; −0.16 mm, P = 0.48, respectively). Conclusion: The results of this study show no significant difference when evaluating current standard and low-dose CT scans using less than one-half the amount ofAbstract : Objectives: To determine whether a substantially lowered radiation protocol would provide satisfactory information for the surgeon, using the distal tibia as a model. Methods: Eleven adult cadaveric distal tibia specimens were used to create Orthopaedic Trauma Association (OTA/AO) 43C distal tibia fractures with varying displacements in 2 planes. Each specimen was scanned at 3 modified protocols, which were then subsequently read by both qualified attending orthopaedists and midlevel residents. Observer reliability was evaluated, as well as confidence levels of identifying fracture pattern and treatment protocols. Results: On average, there was less than a millimeter of variability in the measured gap to true gap as a whole (mean = 0.74 mm, P < 0.0001). With regard to measurements in gap, pattern, and treatment plans, no significant difference was found between CT images acquired with standard (110 mAs) compared with medium (60 mAs; mean 0.0 mm, P = 1.0; k = 0.14, P = 0.56; k = 0.38, P = 0.13, respectively) and low protocols (45 mAs; mean 0.01 mm, P = 0.95; k = 0.24, P = 0.32; k = 0.31, P = 0.13, respectively). Furthermore, no significant difference was found in measuring step-off across standard, medium, and low radiation dose (0.21 mm, P = 0.46; 0.28 mm, P = 0.39; −0.16 mm, P = 0.48, respectively). Conclusion: The results of this study show no significant difference when evaluating current standard and low-dose CT scans using less than one-half the amount of exposure. This suggests that in complex extremity fractures, a new CT protocol may potentially be used. Our initial data show promise that we may retain satisfactory imaging to formulate a treatment plan while also reducing the collective radiation burden to the population. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 31:Issue 8(2017)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 31:Issue 8(2017)
- Issue Display:
- Volume 31, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 8
- Issue Sort Value:
- 2017-0031-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-08
- Subjects:
- radiation dose -- pilon fractures -- periarticular fractures -- radiation reduction -- complex fracture radiation reduction -- CT scan protocol -- CT radiation dose reduction
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000000861 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8042.xml