A Quasi-Experimental, Before-After Trial Examining the Impact of an Emergency Department Mechanical Ventilator Protocol on Clinical Outcomes and Lung-Protective Ventilation in Acute Respiratory Distress Syndrome. Issue 4 (April 2017)
- Record Type:
- Journal Article
- Title:
- A Quasi-Experimental, Before-After Trial Examining the Impact of an Emergency Department Mechanical Ventilator Protocol on Clinical Outcomes and Lung-Protective Ventilation in Acute Respiratory Distress Syndrome. Issue 4 (April 2017)
- Main Title:
- A Quasi-Experimental, Before-After Trial Examining the Impact of an Emergency Department Mechanical Ventilator Protocol on Clinical Outcomes and Lung-Protective Ventilation in Acute Respiratory Distress Syndrome
- Authors:
- Fuller, Brian M.
Ferguson, Ian T.
Mohr, Nicholas M.
Drewry, Anne M.
Palmer, Christopher
Wessman, Brian T.
Ablordeppey, Enyo
Keeperman, Jacob
Stephens, Robert J.
Briscoe, Cristopher C.
Kolomiets, Angelina A.
Hotchkiss, Richard S.
Kollef, Marin H. - Abstract:
- Abstract : Objectives: To evaluate the impact of an emergency department mechanical ventilation protocol on clinical outcomes and adherence to lung-protective ventilation in patients with acute respiratory distress syndrome. Design: Quasi-experimental, before-after trial. Setting: Emergency department and ICUs of an academic center. Patients: Mechanically ventilated emergency department patients experiencing acute respiratory distress syndrome while in the emergency department or after admission to the ICU. Interventions: An emergency department ventilator protocol which targeted variables in need of quality improvement, as identified by prior work: 1) lung-protective tidal volume, 2) appropriate setting of positive end-expiratory pressure, 3) oxygen weaning, and 4) head-of-bed elevation. Measurements and Main Results: A total of 229 patients (186 preintervention group, 43 intervention group) were studied. In the emergency department, the intervention was associated with significant changes ( p < 0.01 for all) in tidal volume, positive end-expiratory pressure, respiratory rate, oxygen administration, and head-of-bed elevation. There was a reduction in emergency department tidal volume from 8.1 mL/kg predicted body weight (7.0–9.1) to 6.4 mL/kg predicted body weight (6.1–6.7) and an increase in lung-protective ventilation from 11.1% to 61.5%, p value of less than 0.01. The intervention was associated with a reduction in mortality from 54.8% to 39.5% (odds ratio, 0.38; 95% CI,Abstract : Objectives: To evaluate the impact of an emergency department mechanical ventilation protocol on clinical outcomes and adherence to lung-protective ventilation in patients with acute respiratory distress syndrome. Design: Quasi-experimental, before-after trial. Setting: Emergency department and ICUs of an academic center. Patients: Mechanically ventilated emergency department patients experiencing acute respiratory distress syndrome while in the emergency department or after admission to the ICU. Interventions: An emergency department ventilator protocol which targeted variables in need of quality improvement, as identified by prior work: 1) lung-protective tidal volume, 2) appropriate setting of positive end-expiratory pressure, 3) oxygen weaning, and 4) head-of-bed elevation. Measurements and Main Results: A total of 229 patients (186 preintervention group, 43 intervention group) were studied. In the emergency department, the intervention was associated with significant changes ( p < 0.01 for all) in tidal volume, positive end-expiratory pressure, respiratory rate, oxygen administration, and head-of-bed elevation. There was a reduction in emergency department tidal volume from 8.1 mL/kg predicted body weight (7.0–9.1) to 6.4 mL/kg predicted body weight (6.1–6.7) and an increase in lung-protective ventilation from 11.1% to 61.5%, p value of less than 0.01. The intervention was associated with a reduction in mortality from 54.8% to 39.5% (odds ratio, 0.38; 95% CI, 0.17–0.83; p = 0.02) and a 3.9 day increase in ventilator-free days, p value equals to 0.01. Conclusions: This before-after study of mechanically ventilated patients with acute respiratory distress syndrome demonstrates that implementing a mechanical ventilator protocol in the emergency department is feasible and associated with improved clinical outcomes. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Critical care medicine. Volume 45:Issue 4(2017)
- Journal:
- Critical care medicine
- Issue:
- Volume 45:Issue 4(2017)
- Issue Display:
- Volume 45, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 4
- Issue Sort Value:
- 2017-0045-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-04
- Subjects:
- acute respiratory distress syndrome -- emergency department -- lung-protective ventilation
Critical care medicine -- Periodicals
Soins intensifs -- Périodiques
616.028 - Journal URLs:
- http://journals.lww.com/ccmjournal/Pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/CCM.0000000000002268 ↗
- Languages:
- English
- ISSNs:
- 0090-3493
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3487.451000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8033.xml