Evaluation of the adsorption and desorption properties of zeolitic imidazolate framework-7 for volatile organic compounds through thermal desorption-gas chromatography. Issue 40 (5th October 2018)
- Record Type:
- Journal Article
- Title:
- Evaluation of the adsorption and desorption properties of zeolitic imidazolate framework-7 for volatile organic compounds through thermal desorption-gas chromatography. Issue 40 (5th October 2018)
- Main Title:
- Evaluation of the adsorption and desorption properties of zeolitic imidazolate framework-7 for volatile organic compounds through thermal desorption-gas chromatography
- Authors:
- Zhao, Ya-Ting
Yu, Li-Qing
Xia, Xin
Yang, Xin-Yu
Hu, Wei
Lv, Yun-Kai - Abstract:
- Abstract : The adsorption/desorption properties of VOCs on ZIF-7 were evaluated by TD-GC. It was found that there are hydrophobic interaction, π–π stacking effect, molecular size effect and "gate-opening" effect between VOCs and ZIF-7. Abstract : The adsorption mechanism and desorption properties of volatile organic compounds (VOCs) in a zeolitic imidazolate framework (ZIF-7) were studied by on-line thermal desorption-gas chromatography (TD-GC), and a high efficiency method for determination of harmful indoor gas levels has been developed. The loading volume, loading flow rate and desorption temperature were optimized. Additionally, ZIF-7 has been proved to be an effective adsorbent and its adsorption performance is superior to that of commercial Tenax TA and activated carbon. It has been proved that ZIF-7 is an ideal adsorbent for VOCs. It was suggested that there are hydrophobic interactions, π–π stacking effects, "gate-opening" effects and molecular size effects between adsorbates and ZIF-7. Therefore, the developed ZIF-7-based TD-GC method offered an excellent performance with a detection limit of 1.22–2.38 ng (S/N = 3), a quantification limit of 4.05–7.94 ng (S/N = 10), and a good linearity ( R 2 = 0.99), and relative standard deviation values (RSD, n = 5) were found to be in the range of 1.69–7.97%, and tube-to-tube reproducibility for three parallel tubes was 8.01%.
- Is Part Of:
- Analytical methods. Volume 10:Issue 40(2018)
- Journal:
- Analytical methods
- Issue:
- Volume 10:Issue 40(2018)
- Issue Display:
- Volume 10, Issue 40 (2018)
- Year:
- 2018
- Volume:
- 10
- Issue:
- 40
- Issue Sort Value:
- 2018-0010-0040-0000
- Page Start:
- 4894
- Page End:
- 4901
- Publication Date:
- 2018-10-05
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c8ay01856a ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 8056.xml