Comparison of Routine Knee Magnetic Resonance Imaging at 3 T and 7 T. Issue 1 (January 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of Routine Knee Magnetic Resonance Imaging at 3 T and 7 T. Issue 1 (January 2017)
- Main Title:
- Comparison of Routine Knee Magnetic Resonance Imaging at 3 T and 7 T
- Authors:
- Springer, Elisabeth
Bohndorf, Klaus
Juras, Vladimir
Szomolanyi, Pavol
Zbýň, Štefan
Schreiner, Markus M.
Schmitt, Benjamin
Trattnig, Siegfried - Abstract:
- Abstract : Objective: The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR] and diagnostic confidence) from a standard knee magnetic resonance imaging (MRI) examination with comparable sequence protocols and acquisition times at 3 T and at 7 T. Materials and Methods: Forty patients experiencing knee pain of unknown etiology underwent comparable MR protocols with standard turbo-spin echo and short tau inversion recovery sequences of the knee joint (5 sequences) at 3 T and 7 T. For quantitative analysis, SNR was determined using these 5 sequences and 3 additional morphological sequences. For a semiquantitative assessment of diagnostic confidence, a diagnostic confidence score (DCS) was assigned, using a 10-point scale. Two experienced radiologists who specialized in musculoskeletal imaging and who were blinded to the field-strength independently assessed 22 potential pathological findings, in total, in 4 anatomically defined areas in the knee joint and rated their diagnostic confidence. Results: In quantitative analysis, all sequences provided higher voxel-volume-adjusted SNR values at 7 T compared with that at 3 T. In semiquantitative analysis, summed DCS values for potential pathological findings in each of the 4 anatomically defined areas were higher at 7 T compared with that at 3 T. There was a statistically significant improvement in the DCS for both readers at 7 T for the diagnosis and exclusion of focal or diffuseAbstract : Objective: The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR] and diagnostic confidence) from a standard knee magnetic resonance imaging (MRI) examination with comparable sequence protocols and acquisition times at 3 T and at 7 T. Materials and Methods: Forty patients experiencing knee pain of unknown etiology underwent comparable MR protocols with standard turbo-spin echo and short tau inversion recovery sequences of the knee joint (5 sequences) at 3 T and 7 T. For quantitative analysis, SNR was determined using these 5 sequences and 3 additional morphological sequences. For a semiquantitative assessment of diagnostic confidence, a diagnostic confidence score (DCS) was assigned, using a 10-point scale. Two experienced radiologists who specialized in musculoskeletal imaging and who were blinded to the field-strength independently assessed 22 potential pathological findings, in total, in 4 anatomically defined areas in the knee joint and rated their diagnostic confidence. Results: In quantitative analysis, all sequences provided higher voxel-volume-adjusted SNR values at 7 T compared with that at 3 T. In semiquantitative analysis, summed DCS values for potential pathological findings in each of the 4 anatomically defined areas were higher at 7 T compared with that at 3 T. There was a statistically significant improvement in the DCS for both readers at 7 T for the diagnosis and exclusion of focal or diffuse grade I or II cartilage defects in the patellar cartilage. For 8 potential pathological findings, a statistically significant difference between the 2 field-strengths could be observed for 1 reader only. For the residual 13 potential pathological findings, there was no statistically significant difference observed. The percentage of concordant ratings was 84.6% at 3 T and 85.4% at 7 T. Conclusions: Ultra-high-field MRI at 7 T improved the overall diagnostic confidence in routine MRI of the knee joint compared with that at 3 T. This is especially true for small joint structures and subtle lesions. Higher spatial resolution was identified as the main reason for this improvement. … (more)
- Is Part Of:
- Investigative radiology. Volume 52:Issue 1(2017:Jan.)
- Journal:
- Investigative radiology
- Issue:
- Volume 52:Issue 1(2017:Jan.)
- Issue Display:
- Volume 52, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 52
- Issue:
- 1
- Issue Sort Value:
- 2017-0052-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-01
- Subjects:
- knee MRI -- ultra-high-field MR -- 7 T -- 3 T and 7 T comparison -- diagnostic confidence score -- cartilage defect -- meniscal tear -- partial and complete tear of the ligaments
Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000303 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8018.xml