Use of a Noise Optimized Monoenergetic Algorithm for Patient-Size Independent Selection of an Optimal Energy Level During Dual-Energy CT of the Pancreas. Issue 1 (January 2017)
- Record Type:
- Journal Article
- Title:
- Use of a Noise Optimized Monoenergetic Algorithm for Patient-Size Independent Selection of an Optimal Energy Level During Dual-Energy CT of the Pancreas. Issue 1 (January 2017)
- Main Title:
- Use of a Noise Optimized Monoenergetic Algorithm for Patient-Size Independent Selection of an Optimal Energy Level During Dual-Energy CT of the Pancreas
- Authors:
- Bellini, Davide
Gupta, Sonia
Ramirez-Giraldo, Juan Carlos
Fu, Wanyi
Stinnett, Sandra S.
Patel, Bhavik
Mileto, Achille
Marin, Daniele - Abstract:
- Abstract : Purpose: To investigate the impact of a second-generation noise-optimized monoenergetic algorithm on selection of the optimal energy level, image quality, and effect of patient body habitus for dual-energy multidetector computed tomography of the pancreas. Materials and Methods: Fifty-nine patients (38 men, 21 women) underwent dual-energy multidetector computed tomography (80/Sn140 kV) in the pancreatic parenchymal phase. Image data sets, at energy levels ranging from 40 to 80 keV (in 5-keV increments), were reconstructed using first-generation and second-generation noise-optimized monoenergetic algorithm. Noise, pancreatic contrast-to-noise ratio (CNRpancreas ), and CNR with a noise constraint (CNRNC ) were calculated and compared among the different reconstructed data sets. Qualitative assessment of image quality was performed by 3 readers. Results: For all energy levels below 70 keV, noise was significantly lower ( P ⩽ 0.05) and CNRpancreas significantly higher ( P < 0.001), with the second-generation monoenergetic algorithm. Furthermore, the second-generation algorithm was less susceptible to variability related to patient body habitus in the selection of the optimal energy level. The maximal CNRpancreas occurred at 40 keV in 98% (58 of 59) of patients with the second-generation monoenergetic algorithm. However, the CNRNC and readers' image quality scores showed that, even with a second-generation monoenergetic algorithm, higher reconstructed energy levelsAbstract : Purpose: To investigate the impact of a second-generation noise-optimized monoenergetic algorithm on selection of the optimal energy level, image quality, and effect of patient body habitus for dual-energy multidetector computed tomography of the pancreas. Materials and Methods: Fifty-nine patients (38 men, 21 women) underwent dual-energy multidetector computed tomography (80/Sn140 kV) in the pancreatic parenchymal phase. Image data sets, at energy levels ranging from 40 to 80 keV (in 5-keV increments), were reconstructed using first-generation and second-generation noise-optimized monoenergetic algorithm. Noise, pancreatic contrast-to-noise ratio (CNRpancreas ), and CNR with a noise constraint (CNRNC ) were calculated and compared among the different reconstructed data sets. Qualitative assessment of image quality was performed by 3 readers. Results: For all energy levels below 70 keV, noise was significantly lower ( P ⩽ 0.05) and CNRpancreas significantly higher ( P < 0.001), with the second-generation monoenergetic algorithm. Furthermore, the second-generation algorithm was less susceptible to variability related to patient body habitus in the selection of the optimal energy level. The maximal CNRpancreas occurred at 40 keV in 98% (58 of 59) of patients with the second-generation monoenergetic algorithm. However, the CNRNC and readers' image quality scores showed that, even with a second-generation monoenergetic algorithm, higher reconstructed energy levels (60–65 keV) represented the optimal energy level. Conclusions: Second-generation noise-optimized monoenergetic algorithm can improve the image quality of lower-energy monoenergetic images of the pancreas, while decreasing the variability related to patient body habitus in selection of the optimal energy level. … (more)
- Is Part Of:
- Journal of computer assisted tomography. Volume 41:Issue 1(2017)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 41:Issue 1(2017)
- Issue Display:
- Volume 41, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2017-0041-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-01
- Subjects:
- dual-energy multidetector CT -- pancreas -- monoenergetic images -- image quality -- patient body habitus
Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000492 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8004.xml