Two-dimensional in vivo rectal dosimetry during high-dose-rate brachytherapy for cervical cancer: a phantom study. (3rd October 2018)
- Record Type:
- Journal Article
- Title:
- Two-dimensional in vivo rectal dosimetry during high-dose-rate brachytherapy for cervical cancer: a phantom study. (3rd October 2018)
- Main Title:
- Two-dimensional in vivo rectal dosimetry during high-dose-rate brachytherapy for cervical cancer: a phantom study
- Authors:
- Jeang, Eun Hee
Goh, Youngmoon
Cho, Kwan Ho
Min, Soonki
Choi, Sang Hyoun
Jeong, Hojin
Jo, Kwanghyun
Lee, Nuri
Song, Sanghyeon
Lee, Se Byeong
Shin, Dongho
Kim, Yeon-Joo
Kim, Joo-Young
Kim, Dae Yong
Hwang, Ui-Jung
Lim, Young Kyung - Abstract:
- Abstract: Background: The aim of the present study was to verify the dosimetric accuracy of two-dimensional (2D) in vivo rectal dosimetry using an endorectal balloon (ERB) with unfoldable EBT3 films for high-dose-rate (HDR) brachytherapy for cervical cancer. The clinical applicability of the technique was discussed. Material and methods: ERB inflation makes the EBT3 films unrolled, whereas its deflation makes them rolled. Patient-specific quality assurance (pQA) tests were performed in 20 patient plans using an Ir-192 remote afterloading system and a water-filled cervical phantom with the ERB. The dose distributions measured in ERBs were compared with those of the treatment plans. Results: The absolute dose profiles measured by the ERBs were in good agreement with those of treatment plans. The global gamma passing rates were 96–100% and 91–100% over 20 pQAs under the criteria of 3%/3 mm and 3%/2 mm, respectively, with a 30% low-dose threshold. Dose-volume histograms of the rectal wall were obtained from the measured dose distributions and showed small volume differences less than 2% on average from the patients' plans over the entire dose interval. The positioning error of the applicator set was detectable with high sensitivity of 12% dose area variation per mm. Additionally, the clinical applicability of the ERB was evaluated in volunteers, and none of them felt any pain when the ERB was inserted or removed. Conclusions: The 2D in vivo rectal dosimetry using the ERB withAbstract: Background: The aim of the present study was to verify the dosimetric accuracy of two-dimensional (2D) in vivo rectal dosimetry using an endorectal balloon (ERB) with unfoldable EBT3 films for high-dose-rate (HDR) brachytherapy for cervical cancer. The clinical applicability of the technique was discussed. Material and methods: ERB inflation makes the EBT3 films unrolled, whereas its deflation makes them rolled. Patient-specific quality assurance (pQA) tests were performed in 20 patient plans using an Ir-192 remote afterloading system and a water-filled cervical phantom with the ERB. The dose distributions measured in ERBs were compared with those of the treatment plans. Results: The absolute dose profiles measured by the ERBs were in good agreement with those of treatment plans. The global gamma passing rates were 96–100% and 91–100% over 20 pQAs under the criteria of 3%/3 mm and 3%/2 mm, respectively, with a 30% low-dose threshold. Dose-volume histograms of the rectal wall were obtained from the measured dose distributions and showed small volume differences less than 2% on average from the patients' plans over the entire dose interval. The positioning error of the applicator set was detectable with high sensitivity of 12% dose area variation per mm. Additionally, the clinical applicability of the ERB was evaluated in volunteers, and none of them felt any pain when the ERB was inserted or removed. Conclusions: The 2D in vivo rectal dosimetry using the ERB with EBT3 films was effective and might be clinically applicable for HDR brachytherapy for cervical and prostate cancers to monitor treatment accuracy and consistency as well as to predict rectal toxicity. … (more)
- Is Part Of:
- Acta oncologica. Volume 57:Number 10(2018)
- Journal:
- Acta oncologica
- Issue:
- Volume 57:Number 10(2018)
- Issue Display:
- Volume 57, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 57
- Issue:
- 10
- Issue Sort Value:
- 2018-0057-0010-0000
- Page Start:
- 1359
- Page End:
- 1366
- Publication Date:
- 2018-10-03
- Subjects:
- Oncology -- Periodicals
Cancer -- Treatment -- Periodicals
616.992 - Journal URLs:
- http://informahealthcare.com/loi/onc ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/0284186X.2018.1484155 ↗
- Languages:
- English
- ISSNs:
- 0284-186X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.705000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8027.xml