Anatomical Applicability of Endovascular Aneurysm Sealing Techniques in a Consecutive Cohort of Fenestrated Endovascular Aneurysm Repairs. (December 2017)
- Record Type:
- Journal Article
- Title:
- Anatomical Applicability of Endovascular Aneurysm Sealing Techniques in a Consecutive Cohort of Fenestrated Endovascular Aneurysm Repairs. (December 2017)
- Main Title:
- Anatomical Applicability of Endovascular Aneurysm Sealing Techniques in a Consecutive Cohort of Fenestrated Endovascular Aneurysm Repairs
- Authors:
- Roy, Iain N.
Gharib, Menatalla
Zerwes, Sebastian
Jakob, Rudolf
Torella, Francesco
McWilliams, Richard G.
Fisher, Robert K. - Abstract:
- Purpose: To determine how many endovascular aneurysm sealing (EVAS) procedures with/without off-label use of chimneys (ChEVAS) could have been performed in a cohort of patients who had undergone fenestrated endovascular aneurysm repair (FEVAR).Methods: Sixty patients (median age 76.3 years; 54 men) who underwent FEVAR in our institution between 2013 and 2015 were selected for the study. The median aneurysm diameter was 62.0 mm (interquartile range 59.3, 69.0). Preoperative computed tomography angiograms (CTA) were anonymized and sent to 2 physicians with experience of more than 40 ChEVAS interventions. These ChEVAS planners were blinded to the study purpose and asked to agree upon an EVAS/ChEVAS plan. The primary outcome was the percentage of the FEVAR patients in whom an EVAS/ChEVAS was technically possible. The secondary outcomes were a comparison of seal zones, number of target vessels, and device cost.Results: An EVAS-based intervention would have been technically possible in 56 (93.3%) of the FEVAR patients. The median proximal aortic seal zone was significantly more distal in the EVAS/ChEVAS procedures vs the FEVAR cases (zone 8 vs zone 7, p<0.001) and fewer target vessels were involved (median 2 vs 3, p<0.001). The cost of the EVAS/ChEVAS device was 66% of the FEVAR device. Planners would not currently advocate an EVAS-based intervention in 43 (76.8%) of these 56 patients due to concerns regarding the risk of migration associated with the lumen thrombus ratiosPurpose: To determine how many endovascular aneurysm sealing (EVAS) procedures with/without off-label use of chimneys (ChEVAS) could have been performed in a cohort of patients who had undergone fenestrated endovascular aneurysm repair (FEVAR).Methods: Sixty patients (median age 76.3 years; 54 men) who underwent FEVAR in our institution between 2013 and 2015 were selected for the study. The median aneurysm diameter was 62.0 mm (interquartile range 59.3, 69.0). Preoperative computed tomography angiograms (CTA) were anonymized and sent to 2 physicians with experience of more than 40 ChEVAS interventions. These ChEVAS planners were blinded to the study purpose and asked to agree upon an EVAS/ChEVAS plan. The primary outcome was the percentage of the FEVAR patients in whom an EVAS/ChEVAS was technically possible. The secondary outcomes were a comparison of seal zones, number of target vessels, and device cost.Results: An EVAS-based intervention would have been technically possible in 56 (93.3%) of the FEVAR patients. The median proximal aortic seal zone was significantly more distal in the EVAS/ChEVAS procedures vs the FEVAR cases (zone 8 vs zone 7, p<0.001) and fewer target vessels were involved (median 2 vs 3, p<0.001). The cost of the EVAS/ChEVAS device was 66% of the FEVAR device. Planners would not currently advocate an EVAS-based intervention in 43 (76.8%) of these 56 patients due to concerns regarding the risk of migration associated with the lumen thrombus ratios observed.Conclusion: EVAS is technically feasible in the majority of patients undergoing FEVAR in our institution but currently advocated in only 23.2%. The seal zone was more distal, fewer target vessels were involved, and the device cost was lower in the planned EVAS/ChEVAS interventions. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 24:Number 6(2017:Dec.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 24:Number 6(2017:Dec.)
- Issue Display:
- Volume 24, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 24
- Issue:
- 6
- Issue Sort Value:
- 2017-0024-0006-0000
- Page Start:
- 773
- Page End:
- 778
- Publication Date:
- 2017-12
- Subjects:
- abdominal aortic aneurysm -- chimney graft -- endovascular aneurysm repair -- endovascular aneurysm sealing -- fenestrated stent-graft -- juxtarenal aneurysm -- pararenal aneurysm -- short proximal neck -- stent-graft -- suprarenal aneurysm
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602817728069 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8005.xml