Energy and exergy analysis of a household refrigerator using a ternary hydrocarbon mixture in tropical environment – Effects of refrigerant charge and capillary length. (25th December 2018)
- Record Type:
- Journal Article
- Title:
- Energy and exergy analysis of a household refrigerator using a ternary hydrocarbon mixture in tropical environment – Effects of refrigerant charge and capillary length. (25th December 2018)
- Main Title:
- Energy and exergy analysis of a household refrigerator using a ternary hydrocarbon mixture in tropical environment – Effects of refrigerant charge and capillary length
- Authors:
- Fatouh, M.
Abou-Ziyan, H. - Abstract:
- Highlights: The refrigerator uses hydrocarbon mixture of R290:R600:R600a of 60:26.6:13.4%. Twenty five combinations of refrigerant charge and capillary tube length are examined. The best charge and capillary tube combination is identified to be 70 g and 4 m. Optimized refrigerator achieves better energy and exergy characteristics than R134a. Constant speed compressor and capillary tube are the main source of exergy destruction. Abstract: This paper examines the energy quality of a household refrigerator working with a ternary hydrocarbon mixture (THM) of 60% propane, 26.6% isobutane, and 13.4% n-butane. Exergy and energy analyses are based on experimental continuous tests of a single evaporator refrigerator for different charges (30–70 g) and capillary tube lengths (4–6 m). The tests are conducted in a climatic chamber at 43 °C and 50% relative humidity. Analysis of experimental data indicated that both THM charge and capillary tube length have substantial effects on the energy and exergy characteristics of refrigerators. The results indicated that exergy efficiency increases as subcooling degree or refrigerant charge increases and as capillary tube length, pressure ratio, and superheating degree decrease. Also, constant speed compressor and capillary tube are responsible for over 88% of refrigerator exergy loss. Refrigerator, using 70 g THM charge and 4 m capillary tube, affords the largest COP, exergy efficiency and cooling capacity and the lowest pressure ratio. Also, itHighlights: The refrigerator uses hydrocarbon mixture of R290:R600:R600a of 60:26.6:13.4%. Twenty five combinations of refrigerant charge and capillary tube length are examined. The best charge and capillary tube combination is identified to be 70 g and 4 m. Optimized refrigerator achieves better energy and exergy characteristics than R134a. Constant speed compressor and capillary tube are the main source of exergy destruction. Abstract: This paper examines the energy quality of a household refrigerator working with a ternary hydrocarbon mixture (THM) of 60% propane, 26.6% isobutane, and 13.4% n-butane. Exergy and energy analyses are based on experimental continuous tests of a single evaporator refrigerator for different charges (30–70 g) and capillary tube lengths (4–6 m). The tests are conducted in a climatic chamber at 43 °C and 50% relative humidity. Analysis of experimental data indicated that both THM charge and capillary tube length have substantial effects on the energy and exergy characteristics of refrigerators. The results indicated that exergy efficiency increases as subcooling degree or refrigerant charge increases and as capillary tube length, pressure ratio, and superheating degree decrease. Also, constant speed compressor and capillary tube are responsible for over 88% of refrigerator exergy loss. Refrigerator, using 70 g THM charge and 4 m capillary tube, affords the largest COP, exergy efficiency and cooling capacity and the lowest pressure ratio. Also, it secures cycle stabilization as it achieves the largest subcooling degree and lowest superheating degree. This household refrigerator achieves better characteristics than those obtained with R134a as it achieves larger COP, exergy efficiency, and cooling capacity by 14%, 3.43%, and 20%, respectively. … (more)
- Is Part Of:
- Applied thermal engineering. Volume 145(2018)
- Journal:
- Applied thermal engineering
- Issue:
- Volume 145(2018)
- Issue Display:
- Volume 145, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 145
- Issue:
- 2018
- Issue Sort Value:
- 2018-0145-2018-0000
- Page Start:
- 14
- Page End:
- 26
- Publication Date:
- 2018-12-25
- Subjects:
- Energy and exergy analysis -- Exergetic efficiency defect -- Ternary hydrocarbon mixture -- Household refrigerator -- Capillary tube -- Refrigerant charge
Heat engineering -- Periodicals
Heating -- Equipment and supplies -- Periodicals
Periodicals
621.40205 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13594311 ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.applthermaleng.2018.09.008 ↗
- Languages:
- English
- ISSNs:
- 1359-4311
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1580.101000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 8004.xml