Accuracy of predicted haemoglobin concentration on cardiopulmonary bypass in paediatric cardiac surgery: effect of different formulae for estimating patient blood volume. (November 2017)
- Record Type:
- Journal Article
- Title:
- Accuracy of predicted haemoglobin concentration on cardiopulmonary bypass in paediatric cardiac surgery: effect of different formulae for estimating patient blood volume. (November 2017)
- Main Title:
- Accuracy of predicted haemoglobin concentration on cardiopulmonary bypass in paediatric cardiac surgery: effect of different formulae for estimating patient blood volume
- Authors:
- Redlin, Matthias
Boettcher, Wolfgang
Dehmel, Frank
Cho, Mi-Young
Kukucka, Marian
Habazettl, Helmut - Abstract:
- Introduction: When applying a blood-conserving approach in paediatric cardiac surgery with the aim of reducing the transfusion of homologous blood products, the decision to use blood or blood-free priming of the cardiopulmonary bypass (CPB) circuit is often based on the predicted haemoglobin concentration (Hb) as derived from the pre-CPB Hb, the prime volume and the estimated blood volume. We assessed the accuracy of this approach and whether it may be improved by using more sophisticated methods of estimating the blood volume. Patients and Methods: Data from 522 paediatric cardiac surgery patients treated with CPB with blood-free priming in a 2-year period from May 2013 to May 2015 were collected. Inclusion criteria were body weight <15 kg and available Hb data immediately prior to and after the onset of CPB. The Hb on CPB was predicted according to Fick's principle from the pre-CPB Hb, the prime volume and the patient blood volume. Linear regression analyses and Bland-Altman plots were used to assess the accuracy of the Hb prediction. Different methods to estimate the blood volume were assessed and compared. Results: The initial Hb on CPB correlated well with the predicted Hb (R 2 =0.87, p<0.001). A Bland-Altman plot revealed little bias at 0.07 g/dL and an area of agreement from -1.35 to 1.48 g/dL. More sophisticated methods of estimating blood volume from lean body mass did not improve the Hb prediction, but rather increased bias. Conclusion: Hb prediction is reasonablyIntroduction: When applying a blood-conserving approach in paediatric cardiac surgery with the aim of reducing the transfusion of homologous blood products, the decision to use blood or blood-free priming of the cardiopulmonary bypass (CPB) circuit is often based on the predicted haemoglobin concentration (Hb) as derived from the pre-CPB Hb, the prime volume and the estimated blood volume. We assessed the accuracy of this approach and whether it may be improved by using more sophisticated methods of estimating the blood volume. Patients and Methods: Data from 522 paediatric cardiac surgery patients treated with CPB with blood-free priming in a 2-year period from May 2013 to May 2015 were collected. Inclusion criteria were body weight <15 kg and available Hb data immediately prior to and after the onset of CPB. The Hb on CPB was predicted according to Fick's principle from the pre-CPB Hb, the prime volume and the patient blood volume. Linear regression analyses and Bland-Altman plots were used to assess the accuracy of the Hb prediction. Different methods to estimate the blood volume were assessed and compared. Results: The initial Hb on CPB correlated well with the predicted Hb (R 2 =0.87, p<0.001). A Bland-Altman plot revealed little bias at 0.07 g/dL and an area of agreement from -1.35 to 1.48 g/dL. More sophisticated methods of estimating blood volume from lean body mass did not improve the Hb prediction, but rather increased bias. Conclusion: Hb prediction is reasonably accurate, with the best result obtained with the simplest method of estimating the blood volume at 80 mL/kg body weight. When deciding for or against blood-free priming, caution is necessary when the predicted Hb lies in a range of ± 2 g/dL around the transfusion trigger. … (more)
- Is Part Of:
- Perfusion. Volume 32:Number 8(2017)
- Journal:
- Perfusion
- Issue:
- Volume 32:Number 8(2017)
- Issue Display:
- Volume 32, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 32
- Issue:
- 8
- Issue Sort Value:
- 2017-0032-0008-0000
- Page Start:
- 639
- Page End:
- 644
- Publication Date:
- 2017-11
- Subjects:
- paediatric cardiac surgery -- cardiopulmonary bypass -- predicted Hb -- blood free priming -- Bland-Altman plot
Perfusion (Physiology) -- Periodicals
Blood -- Circulation, Artificial -- Periodicals
Heart -- Surgery -- Periodicals
Extracorporeal Circulation -- Periodicals
Perfusion -- Periodicals
Circulation extracorporelle -- Périodiques
Perfusion -- Périodiques
617.41 - Journal URLs:
- http://prf.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0267659117714861 ↗
- Languages:
- English
- ISSNs:
- 0267-6591
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7970.xml