Detection of mental fatigue state with wearable ECG devices. (November 2018)
- Record Type:
- Journal Article
- Title:
- Detection of mental fatigue state with wearable ECG devices. (November 2018)
- Main Title:
- Detection of mental fatigue state with wearable ECG devices
- Authors:
- Huang, Shitong
Li, Jia
Zhang, Pengzhu
Zhang, Weiqiang - Abstract:
- Highlights: This paper aims to investigate the possibility of using wearable smart electrocardiogram (ECG) devices to detect the mental fatigue state. In total, 35 healthy participants were recruited from a public university in East China. Throughout the entire experiment, each participant wore a wearable device that was further linked to a smartphone to upload the data based on Bluetooth transmission. Eight heart rate variability (HRV) indicators were collected at intervals of 5 min throughout the entire experiment. Four algorithms, support vector machine (SVM), K-nearest neighbor (KNN), naïve Bayes (NB), and logistic regression (LR), were used to build classifiers that automatically detected the fatigue state. The best performance was achieved by KNN. The NN.mean (mean of normal to normal interval), PNN50 (the proportion of NN50 divided by total number of NNs), TP (total spectral power), and LF (low frequency from 0.04 Hz to 0.15 Hz) were the most important HRV indicators for mental fatigue detection. Abstract: Overwork-related disorders, such as cerebrovascular/cardiovascular diseases (CCVD) and mental disorders due to overwork, are a major occupational and public health issue worldwide, particularly in East Asian countries. Since wearable smart devices are inexpensive, convenient, popular and widely available today, we were interested in investigating the possibility of using wearable smart electrocardiogram (ECG) devices to detect the mental fatigue state. In total, 35Highlights: This paper aims to investigate the possibility of using wearable smart electrocardiogram (ECG) devices to detect the mental fatigue state. In total, 35 healthy participants were recruited from a public university in East China. Throughout the entire experiment, each participant wore a wearable device that was further linked to a smartphone to upload the data based on Bluetooth transmission. Eight heart rate variability (HRV) indicators were collected at intervals of 5 min throughout the entire experiment. Four algorithms, support vector machine (SVM), K-nearest neighbor (KNN), naïve Bayes (NB), and logistic regression (LR), were used to build classifiers that automatically detected the fatigue state. The best performance was achieved by KNN. The NN.mean (mean of normal to normal interval), PNN50 (the proportion of NN50 divided by total number of NNs), TP (total spectral power), and LF (low frequency from 0.04 Hz to 0.15 Hz) were the most important HRV indicators for mental fatigue detection. Abstract: Overwork-related disorders, such as cerebrovascular/cardiovascular diseases (CCVD) and mental disorders due to overwork, are a major occupational and public health issue worldwide, particularly in East Asian countries. Since wearable smart devices are inexpensive, convenient, popular and widely available today, we were interested in investigating the possibility of using wearable smart electrocardiogram (ECG) devices to detect the mental fatigue state. In total, 35 healthy participants were recruited from a public university in East China. Throughout the entire experiment, each participant wore a wearable device that was further linked to a smartphone to upload the data based on Bluetooth transmission. To manipulate the fatigue state, each participant was asked to finish a quiz, which lasted for approximately 80 min, with 30 logical referential and computing problems and 25 memory tests. Eight heart rate variability (HRV) indicators namely NN.mean (mean of normal to normal interval), rMSSD (root mean square of successive differences), PNN50 (the proportion of NN50 divided by total number of NNs), TP (total spectral power), HF (high frequency from 0.15 Hz to 0.4 Hz), LF (low frequency from 0.04 Hz to 0.15 Hz), VLF (very low frequency from 0.0033 Hz to 0.04 Hz) and the LF/HF ratio were collected at intervals of 5 min throughout the entire experiment. After the feature selection was performed, six indicators remained for further analysis, which were the NN.mean, rMSSD, PNN50, TP, LF, and VLF. Four algorithms, support vector machine (SVM), K-nearest neighbor (KNN), naïve Bayes (NB), and logistic regression (LR), were used to build classifiers that automatically detected the fatigue state. The best performance was achieved by KNN, which had a CV accuracy of 75.5%. The NN.mean, PNN50, TP and LF were the most important HRV indicators for mental fatigue detection. KNN performed the best among the four algorithms and had an average CV accuracy of 65.37% for all of the possible feature combinations. … (more)
- Is Part Of:
- International journal of medical informatics. Volume 119(2018)
- Journal:
- International journal of medical informatics
- Issue:
- Volume 119(2018)
- Issue Display:
- Volume 119, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 119
- Issue:
- 2018
- Issue Sort Value:
- 2018-0119-2018-0000
- Page Start:
- 39
- Page End:
- 46
- Publication Date:
- 2018-11
- Subjects:
- Mental fatigue -- Wearable devices -- ECG -- HRV -- Feature selection -- Machine learning
Medical informatics -- Periodicals
Information science -- Periodicals
Computers -- Periodicals
Medical technology -- Periodicals
Medical Informatics -- Periodicals
Technology, Medical -- Periodicals
Computers
Information science
Medical informatics
Medical technology
Electronic journals
Periodicals
Electronic journals
610.285 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13865056 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13865056 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13865056 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijmedinf.2018.08.010 ↗
- Languages:
- English
- ISSNs:
- 1386-5056
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.345250
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7966.xml