Monte Carlo dose in a prosthesis phantom based on exact geometry vs streak artefact contaminated CT data as benchmarked against Gafchromic film measurements. (October 2018)
- Record Type:
- Journal Article
- Title:
- Monte Carlo dose in a prosthesis phantom based on exact geometry vs streak artefact contaminated CT data as benchmarked against Gafchromic film measurements. (October 2018)
- Main Title:
- Monte Carlo dose in a prosthesis phantom based on exact geometry vs streak artefact contaminated CT data as benchmarked against Gafchromic film measurements
- Authors:
- Ade, Nicholas
Oderinde, O.M.
du Plessis, F.C.P. - Abstract:
- Highlights: Effect of CT metal artefacts on MC dose in a pelvic prosthesis phantom is studied. 15 MeV electron and 10 MV photon therapy beams were used. An artefact-free phantom model with exactly known materials was reconstructed. For unilateral hip Ti implant, metal artefacts could cause dose errors of about 3%. Abstract: Purpose: In radiotherapy, accurate calculation of patient radiation dose is very important for good clinical outcome. In the presence of metallic implants, the dose calculation accuracy could be compromised by metal artefacts generated in computed tomography (CT) images of patients. This study investigates the influence of metal-induced CT artefacts on MC dose calculations in a pelvic prosthesis phantom. Methods: A pelvic phantom containing unilateral Ti prosthesis was CT-scanned and accurate Hounsfield unit (HU) values were assigned to known materials of the phantom as opposed to HU values produced through the artefact CT images of the phantom. Using the DOSXYZnrc MC code, dose calculations were computed in the phantom model constructed from the original CT images containing the artefacts and artefact-free images made from the exact geometry of the phantom with known materials. The dose calculations were benchmarked against Gafchromic EBT3 film measurements using 15 MeV electron and 10 MV photon beams. Results: The average deviations between film and MC dose data decreased from 3 ± 2% to 1 ± 1% and from about 6 ± 2% to 3 ± 1% for the artefact andHighlights: Effect of CT metal artefacts on MC dose in a pelvic prosthesis phantom is studied. 15 MeV electron and 10 MV photon therapy beams were used. An artefact-free phantom model with exactly known materials was reconstructed. For unilateral hip Ti implant, metal artefacts could cause dose errors of about 3%. Abstract: Purpose: In radiotherapy, accurate calculation of patient radiation dose is very important for good clinical outcome. In the presence of metallic implants, the dose calculation accuracy could be compromised by metal artefacts generated in computed tomography (CT) images of patients. This study investigates the influence of metal-induced CT artefacts on MC dose calculations in a pelvic prosthesis phantom. Methods: A pelvic phantom containing unilateral Ti prosthesis was CT-scanned and accurate Hounsfield unit (HU) values were assigned to known materials of the phantom as opposed to HU values produced through the artefact CT images of the phantom. Using the DOSXYZnrc MC code, dose calculations were computed in the phantom model constructed from the original CT images containing the artefacts and artefact-free images made from the exact geometry of the phantom with known materials. The dose calculations were benchmarked against Gafchromic EBT3 film measurements using 15 MeV electron and 10 MV photon beams. Results: The average deviations between film and MC dose data decreased from 3 ± 2% to 1 ± 1% and from about 6 ± 2% to 3 ± 1% for the artefact and artefact-free phantom models against film data for the electron and photon fields, respectively. Conclusions: For the Ti prosthesis phantom, the presence of metal-induced CT artefacts could cause dose inaccuracies of about 3%. Construction of an artefact-free phantom model made from the exact geometry of the phantom with known materials to overcome the effect of artefacts is advantageous compared to using CT data directly of which the exact tissue composition is not well-known. … (more)
- Is Part Of:
- Physica medica. Volume 54(2018)
- Journal:
- Physica medica
- Issue:
- Volume 54(2018)
- Issue Display:
- Volume 54, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 54
- Issue:
- 2018
- Issue Sort Value:
- 2018-0054-2018-0000
- Page Start:
- 94
- Page End:
- 102
- Publication Date:
- 2018-10
- Subjects:
- Prosthesis phantom -- CT artefacts -- Monte Carlo -- EBT3 film
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2018.09.124 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 7970.xml