Low-cost multifrequency electrical impedance-based system (MFEIBS) for clinical imaging: design and performance evaluation. (19th May 2018)
- Record Type:
- Journal Article
- Title:
- Low-cost multifrequency electrical impedance-based system (MFEIBS) for clinical imaging: design and performance evaluation. (19th May 2018)
- Main Title:
- Low-cost multifrequency electrical impedance-based system (MFEIBS) for clinical imaging: design and performance evaluation
- Authors:
- Singh, Gurmeet
Anand, Sneh
Lall, Brejesh
Srivastava, Anurag
Singh, Vaneet - Abstract:
- Abstract: Electrical impedance tomography (EIT) is an upcoming and capable imaging modality used for clinical imaging. It is non-invasive, non-ionising and an inexpensive technique. This paper explains the designing and the analysis of a low-cost multifrequency electrical impedance-based system (MFEIBS) having a flexible mechanism of interfacing up to 32 electrodes, suitable for 1 kHz–2 MHz. Various indicators to check the performance of the EIT system were evaluated and presented here. The performance of VCO and VCCS was measured up to 2 MHz. SNR was measured with saline phantom and its mean value is 74 dB for the complete bandwidth. Different combinations of resistors and capacitors were used to find the accuracy of the system, and relative error was less than 0.55% for the entire range. CMRR of the system was calculated and it was found to be maximum 85 dB at 1 kHz frequency. A 16-electrode circular plastic phantom having a diameter of 18 cm was established and connected with a simple MFEIBS. Obtained surface potential was applied to the computer used for image formation using NI USB-6259, 16-bit, 1.25 MS/s M Series High-speed DAQ. Images reconstructed using the system presented in this paper was generated from a 16-electrode plastic phantom filled with NaCl up to 1.2 cm height.
- Is Part Of:
- Journal of medical engineering & technology. Volume 42:Number 4(2018)
- Journal:
- Journal of medical engineering & technology
- Issue:
- Volume 42:Number 4(2018)
- Issue Display:
- Volume 42, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 42
- Issue:
- 4
- Issue Sort Value:
- 2018-0042-0004-0000
- Page Start:
- 274
- Page End:
- 289
- Publication Date:
- 2018-05-19
- Subjects:
- Electrical impedance tomography -- VCO -- multifrequency -- practical phantom -- boundary data
Biomedical engineering -- Periodicals
Medical technology -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/journal/jmt ↗
http://www.tandfonline.com/toc/ijmt20/current ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/03091902.asp ↗ - DOI:
- 10.1080/03091902.2018.1478008 ↗
- Languages:
- English
- ISSNs:
- 0309-1902
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5017.057000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 7970.xml